Introduction: Since its introduction into clinical use, the efficacy of electronic fetal heart rate (FHR) monitoring (EFM) has been questionable. This has been due partly to the marked variation in interpretation of the FHR pattern and subsequent decisions for obstetric intervention, (e.g., the need for prompt delivery). Current application of EFM is limited to the assessment of FHR patterns and uterine contractions. Recent development of higher-order FHR analysis has yielded monitoring systems that can add automated fetal electrocardiographic ST segment analysis to the standard FHR and uterine contraction information. Our goal was to evaluate the effect of adding ST segment analysis to standard FHR information on observer agreement for clinical decision making.
Methods: Seven practitioners who were trained and experienced in combined FHR and ST monitoring reviewed 51 fetal monitor tracings, ranging from 2 to 4 h in length. Reviews were conducted in two sessions and at different times. The first session presented only the FHR and uterine contraction information, following which the participants determined the time at which intervention (decision for operative vaginal or Cesarean section delivery) was indicated. In the second session, the participants were provided with a randomized sequence of the same tracings with the addition of ST segment information, as produced by the STAN monitor system (Neoventa Medical, Gothenburg, Sweden). Observer agreement was based on the proportion of participants who agreed on the need for an intervention, and the per cent agreement on the timing of the intervention within 20 min before or after the median time of intervention.
Results: Of the 51 cases included in this study there were ten fetuses with umbilical artery (UA) pH between 7.05 and 7.14, and nine with UA pH of < 7.05. Observer agreement increased significantly for required intervention when the ST segment information was available for tracing analysis as compared with review of the standard tracing alone (0.96 vs. 0.80, p < 0.05) and the timing of intervention (0.92 vs. 0.66, respectively, p < 0.05). Similarly, correct identification for needed interventions on fetuses with abnormal outcomes increased from 86 to 93% while unneeded interventions on normal fetuses decreased from 43 to 6%.
Conclusion: The addition of ST analysis to standard FHR monitoring improves observer consistency in both the decision for and timing of obstetric interventions. The incorporation of ST segment data with the standard FHR tracing may reduce the number of unneeded obstetric interventions when fetal compromise is absent.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1080/14767050410001668284 | DOI Listing |
Fetal Diagn Ther
December 2024
Department of Medicine and Surgery, Obstetrics and Gynecology Unit, University of Parma, Parma, Italy.
Introduction: Fetal scalp electrode (FSE) is considered the gold standard for the intrapartum monitoring of the fetal heart rate (FHR) being associated with the lowest rate of signal loss and artifacts including the recording of the maternal heart rate. FSE acquires a fetal electrocardiogram and evaluates the time intervals between successive R waves. As such, it allows the recording of the beat-to-beat fluctuation of the FHR.
View Article and Find Full Text PDFBJOG
November 2024
Department of Women's and Children's Health, King's College London, London, UK.
Objective: Establish whether pregnancies complicated by gestational diabetes mellitus (GDM) are associated with a fetal cardiac phenotype that predisposes to arrhythmia; utilising measurements derived from non-invasive abdominal fetal ECG.
Design: Prospective observational study.
Setting: Three tertiary obstetric units, United Kingdom.
Am J Perinatol
December 2024
Rabin Medical Center, Helen Schneider Hospital for Women, Petach Tikva, Israel.
Objective: Pulsenmore ES is a self-scanning ultrasound (US) system for remote fetal assessment. It comprises a handheld transducer that serves as a smartphone cradle coupled with an application and clinician's web-viewer dashboard. Recently, a novel capability was added to the system allowing offline fetal heart rate (FHR) and maximal vertical pocket (MVP) measurements.
View Article and Find Full Text PDFInterdiscip Sci
December 2024
National Heart Research Institute Singapore, National Heart Centre Singapore, Singapore, 169609, Singapore.
Cardiotocography (CTG) is used to assess the health of the fetus during birth or antenatally in the third trimester. It concurrently detects the maternal uterine contractions (UC) and fetal heart rate (FHR). Fetal distress, which may require therapeutic intervention, can be diagnosed using baseline FHR and its reaction to uterine contractions.
View Article and Find Full Text PDFSci Rep
June 2024
Obstetric Diagnostics and Therapeutics Group, Department of Obstetrics and Gynaecology, The University of Melbourne, Heidelberg, 3084, VIC, Australia.
Standard clinical practice to assess fetal well-being during labour utilises monitoring of the fetal heart rate (FHR) using cardiotocography. However, visual evaluation of FHR signals can result in subjective interpretations leading to inter and intra-observer disagreement. Therefore, recent studies have proposed deep-learning-based methods to interpret FHR signals and detect fetal compromise.