A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Closure of skin incisions in rabbits by laser soldering II: Tensile strength. | LitMetric

Closure of skin incisions in rabbits by laser soldering II: Tensile strength.

Lasers Surg Med

Maurice and Gabriela Goldschleger School of Dental Medicine, Tel Aviv University, Tel Aviv 69978, Israel.

Published: June 2005

Background And Objectives: The basic characteristic property of wound closure is the immediate and long-term tensile strength (LTS). The objective of the current study was to compare tissue laser soldering to other available methods (i.e., cyanoacrylate glues and sutures) in the performance and outcome of wound closure and reparative healing process, with an emphasis on the immediate and LTS.

Study Design/materials And Methods: The animals were divided into three groups according to the type and details of the closure procedure. Group A: laser treatments at different temperatures were compared to sutured incisions, emphasizing the LTS after 10 days. Group B: laser soldering at 65 +/- 5 degrees C was compared to chemical glues (i.e., Histoacryl and Dermabond), emphasizing the immediate tensile strength (ITS). Group C: LTS of laser soldered incisions was compared to that of sutured incisions at various time intervals emphasizing LTS (3, 7, 14, 28 days).

Results: Group A: LTS at 60 degrees C exhibited the highest values (0.48 MPa). Group B: no ITS difference was detected between laser soldering and chemical glues. Group C: soldered incisions at 65 degrees C exhibited higher LTS (1.81 MPa) than that of sutured incisions (1.08 MPa) (P < 0.043).

Conclusions: Temperature-controlled laser soldering at 65 degrees C provided sufficient ITS and higher bonding LTS values compared with sutures, resulting in better wound healing characteristics. The laser soldering system presented here should be tested on larger animal models before adopting it for clinical usage.

Download full-text PDF

Source
http://dx.doi.org/10.1002/lsm.20073DOI Listing

Publication Analysis

Top Keywords

laser soldering
24
tensile strength
12
sutured incisions
12
laser
8
wound closure
8
group laser
8
compared sutured
8
emphasizing lts
8
chemical glues
8
group lts
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!