The effectiveness of implantable cardioverter defibrillators (ICDs) implanted in the early postoperative period after cardiac surgery for ventricular tachyarrhythmias is unknown, because all of the major trials excluded this patient population. Thus, a 10-year retrospective study was conducted of patients who had ICDs implanted for de novo postoperative ventricular tachyarrhythmias during the index admission for cardiac surgery. There was a high rate of early recurrence of ventricular tachyarrhythmia treated by defibrillators, and this finding questions the exclusion of this important patient population from large trials.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.amjcard.2004.04.041DOI Listing

Publication Analysis

Top Keywords

postoperative ventricular
8
ventricular tachyarrhythmia
8
icds implanted
8
cardiac surgery
8
ventricular tachyarrhythmias
8
patient population
8
effectiveness early
4
early implantation
4
implantation cardioverter
4
cardioverter defibrillator
4

Similar Publications

Purpose: Pediatric patients undergoing neurosurgery pose risk of perioperative hemorrhage and clotting dysfunction which is increased in tumors with high vascularity, endothelial exposure, and necrosis. Lesions affecting the ventricular system may arise from several etiologies, including rare tumors. The present study aimed to study the preoperative coagulation and transfusion profile of pediatric patients undergoing neurosurgery for intraventricular lesions.

View Article and Find Full Text PDF

Ventricular assist device (VAD) and cardiac transplant patients experience significant strain on their physical and mental wellbeing postoperatively. Mental health and substance use disorders (MHDs and SUDs) have substantial effects on the quality of life and compliance of transplant and VAD patients. In this study, we compare and characterize MHDs and SUDs between VAD and cardiac allograft patients and transplant list patients with and without VADs.

View Article and Find Full Text PDF

Purpose: Advancements in minimally invasive technologies to decrease postoperative morbidity and recovery times represent a large opportunity for mitral valve repair operations. However, current technologies are unable to replicate gold standard surgical neochord implantation.

Methods: We developed a novel neochordal repair device, Minimally Invasive Ventricular Anchoring Neochordoplasty (MIVAN), which operates via transcatheter, trans-septal anchoring to the posterior ventricular wall.

View Article and Find Full Text PDF
Article Synopsis
  • The aim of the study was to create a reproducible animal model of tricuspid regurgitation (TR) using a self-expanding nickel-titanium stent.
  • The experiment involved 10 pigs, 7 in the experimental group undergoing TR induction through stent implantation, while 3 served as controls without the stent.
  • Results showed significant changes in cardiac structure and function in the experimental group, indicating successful model establishment with no fatalities, making this approach effective for further research on right ventricular issues.
View Article and Find Full Text PDF

The benefits of permanent cardiac pacing have been widely demonstrated. However, the literature on complications remains inconsistent. We lack precise information about the frequency of complications and their predictive factors in our center.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!