Feedback from muscles stimulates ventilation at the onset of passive movement. We hypothesized that central neural activity via a cognitive task source would interact with afferent feedback, and we tested this hypothesis by examining the fast changes in ventilation at the transition from rest to passive leg movement, under two conditions: 1) no task and 2) solving a computer-based puzzle. Resting breathing was greater in condition 2 than in condition 1, evidenced by an increase in mean +/- SE breathing frequency (18.2 +/- 1.1 vs. 15.0 +/- 1.2 breaths/min, P = 0.004) and ventilation (10.93 +/- 1.16 vs. 9.11 +/- 1.17 l/min, P < 0.001). In condition 1, the onset of passive movement produced a fast increase in mean +/- SE breathing frequency (change of 2.9 +/- 0.4 breaths/min, P < 0.001), tidal volume (change of 233 +/- 95 ml, P < 0.001), and ventilation (change of 6.00 +/- 1.76 l/min, P < 0.001). However, in condition 2, the onset of passive movement only produced a fast increase in mean +/- SE breathing frequency (change of 1.3 +/- 0.4 breaths/min, P = 0.045), significantly smaller than in condition 1 (P = 0.007). These findings provide evidence for an interaction between central neural cognitive activity and the afferent feedback mechanism, and we conclude that the performance of a cognitive task suppresses the respiratory response to passive movement.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1152/japplphysiol.00302.2004 | DOI Listing |
Physiother Res Int
January 2025
Department of Biomedical Engineering, University of Engineering and Technology (UET) Lahore, Narowal Campus, Narowal, Pakistan.
Background And Purpose: Throwing a baseball involves intense exposure of the arm to high speeds and powerful forces, which contributes to an increasing prevalence of arm injuries among athletes. Traditional rigid exoskeletons and rehabilitation equipment frequently lack portability, safety, ergonomic design, and affordability. Traditional rehabilitation approaches frequently require therapist monitoring, resulting in therapy delays.
View Article and Find Full Text PDFBackground: Contamination of sterilized surgical instruments is not a typically suspected source of increased infection rate, especially if no abnormalities in the sterilization process are detected.
Purpose/hypothesis: The purpose of this study was to report increased infection rates after knee ligament reconstructions due to undetectable sterilization process errors leading to residual moisture, not limited to a specific surgical tool. It was hypothesized that (1) residual moisture on surgical tools due to autoclave overloading would not be detected by autoclave self-diagnostics, chemical and biological tests, or organoleptic assessment and (2) this kind of contamination may elevate infection rates, especially in knee intra-articular reconstruction procedures.
Chiropr Man Therap
January 2025
Department of Chiropractic Medicine, Integrative Spinal Research Group, Balgrist University Hospital, University of Zurich, Zurich, Switzerland.
Background: Spinal manipulation (MAN) and mobilization (MOB) are biomechanically different yet both elicit pain reduction and increased range of motion. Previous investigations have focused on quantifying kinetics (e.g.
View Article and Find Full Text PDFBMC Musculoskelet Disord
January 2025
Pediatric Orthopedic Hospital, Honghui Hospital, Xi'an Jiao tong University, Xi'an, 710000, China.
Background: Supracondylar humerus fractures (SCHFs) are the most common elbow fractures in children and are typically treated with closed reduction and Kirschner pin fixation. However, varying degrees of residual rotational displacement may remain after closed reduction. Several methods exist to assess rotational displacement, but none account for the effect of elbow rotation on the results.
View Article and Find Full Text PDFBMC Oral Health
January 2025
Department of Stomatology, The First Affiliated Hospital, Sun Yat-Sen University, Guangzhou, 510080, China.
Background: Proper torque control is crucial to the outcome of orthodontic treatment. This study aimed to employ finite element analysis to compare the torque capabilities of a novel spherical self-ligating bracket with a lock-hook system against those of commonly used passive self-ligating and conventional bracket systems, as well as to reveal the biomechanical changes in the periodontal ligament (PDL) during torque expression.
Methods: A maxillary right central incisor, along with its PDL and alveolar bone, were modeled.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!