CT angiography for evaluation of living renal donors: comparison of four reconstruction methods.

AJR Am J Roentgenol

Department of Radiology, Asan Medical Center, University of Ulsan, College of Medicine, 388-1 Poongnap-dong, Songpa-gu, Seoul 138-736, South Korea.

Published: August 2004

Objective: We sought to compare various reconstruction methods for CT angiographic images in evaluating living renal donors.

Materials And Methods: In 76 patients who underwent donor nephrectomy, vascular phase CT data were obtained using an MDCT scanner (detector array, 1.25 mm x 4; beam pitch, 1.5). Two radiologists independently reconstructed CT angiographic images using thick-slab volume rendering, thick-slab maximum intensity projection (MIP), sliding thin-slab volume rendering, and sliding thin-slab MIP. The radiologists counted the number of renal arteries, early branching arteries, and renal veins. We compared the accuracy rates for the detection of vessels achieved with the four types of reconstructed images, using the surgical findings as the gold standard. Agreement between the two observers and between the surgical and CT angiographic findings was evaluated.

Results: The sensitivity for detecting the supernumerary artery was significantly greater with sliding thin-slab volume rendering and sliding thin-slab MIP (97%) than with thick-slab volume rendering (59%) (p = 0.039). No significant difference between the other comparison pairs of reconstruction methods was found. The interobserver agreement for detecting supernumerary and early branching arteries with sliding thin-slab volume rendering and MIP was excellent (kappa = 0.820-0.859) and good for renal veins (kappa = 0.698-0.724), whereas the agreement of thick-slab volume rendering and MIP was good for arteries (kappa = 0.706-0.791) and moderate for veins (kappa = 0.443-0.579). The agreement between CT angiographic reconstructed images and surgical findings for detection of vessels was better with sliding thin-slab volume rendering and MIP (kappa = 0.793-1.000) than in thick-slab volume rendering and MIP (kappa = 0.306-0.613).

Conclusion: For CT angiographic evaluation of living renal donors, sliding thin-slab reconstruction is superior to thick-slab reconstruction.

Download full-text PDF

Source
http://dx.doi.org/10.2214/ajr.183.2.1830471DOI Listing

Publication Analysis

Top Keywords

volume rendering
32
sliding thin-slab
28
thick-slab volume
16
thin-slab volume
16
rendering mip
16
living renal
12
reconstruction methods
12
evaluation living
8
renal donors
8
angiographic images
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!