Accompanying the brilliance-upgrading project at the Photon Factory storage ring, the beam-position monitor (BPM) system has been renovated. The new system was designed to enable precise and fast measurements to correct the closed-orbit distortion (COD), as well as to feed back the orbit position during user runs. There are 42 BPMs newly installed, amounting to a total of 65 BPMs. All of the BPMs are calibrated on the test bench using a coaxially strung metallic wire. The measured electrical offsets are typically 200 micro m in both directions, which is 1/2-1/3 of those of the old-type BPMs. In the signal-processing system, PIN diode switches are employed in order to improve reliability. In the fastest mode, this system is capable of measuring COD within about 10 ms; this fast acquisition will allow fast suppression of the beam movement for frequencies up to 50 Hz using a global feedback system.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1107/S0909049597014349 | DOI Listing |
Rev Sci Instrum
December 2024
Institute of Applied Electronics, China Academy of Engineering Physics, P.O. Box 919-1007, Mianyang 621900, China.
We developed a wideband RF cavity beam position monitor (CBPM) with a 217 MHz bandwidth centered at the 4.875 GHz dipole mode frequency as part of the preliminary research for a high-repetition-rate hard x-ray free electron laser project at the Chinese Academy of Engineering Physics. This paper presents new results demonstrating bunch-by-bunch position measurements on electron bunches spaced by 2.
View Article and Find Full Text PDFJ Synchrotron Radiat
January 2025
S.RI.Tech, Viale Del Lavoro 42A, 35010 Vigonza, Italy.
J Synchrotron Radiat
November 2024
Paul Scherrer Institute PSI, Forschungsstrasse 111, 5232 Villigen PSI, Switzerland.
The upgrade of the Swiss Light Source, called SLS 2.0, necessitates comprehensive updates to all 18 user front ends. This upgrade is driven by the increased power of the synchrotron beam, reduced floor space, changing source points, new safety regulations and enhanced beam properties, including a brightness increase by up to a factor of 40.
View Article and Find Full Text PDFJ Radiat Res
December 2024
Faculty of Engineering, Hokkaido University, Kita 13, Nishi 8, Kita-ku, Sapporo, Hokkaido 060-8628, Japan.
J Synchrotron Radiat
September 2024
Pohang Accelerator Laboratory, POSTECH, Pohang, Gyeongbuk 37673, Republic of Korea.
The Pohang Accelerator Laboratory X-ray Free-Electron Laser (PAL-XFEL) operates hard X-ray and soft X-ray beamlines for conducting scientific experiments providing intense ultrashort X-ray pulses based on the self-amplified spontaneous emission (SASE) process. The X-ray free-electron laser is characterized by strong pulse-to-pulse fluctuations resulting from the SASE process. Therefore, online photon diagnostics are very important for rigorous measurements.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!