Cardiac pacing is a proven and effective treatment in the management of many cardiac arrhythmias. Implantable cardiac defibrillators (ICDs) are beneficial for certain patient groups with a history of serious, recurrent ventricular dysrhythmias, with a high risk of sudden cardiac death. Pacemaker devices take many forms and are highly visible on the chest radiograph. The radiographic appearances of ICDs and pacemakers can be similar and are subject to similar complications. The anatomical approach to the implantation, the type of device used and anatomical variations will all affect the appearance of these devices on the chest film. Pacemaker complications identified radiographically include pneumothorax, lead malpositioning, lead displacement or fracture, fracture of outer conductor coil, loose connection between the lead and pacemaker connector block, lack of redundant loops in paediatric patients and excessive manipulation of the device by the patient (Twiddler's syndrome). This pictorial review highlights the role of chest radiography in the diagnosis of post-cardiac pacing and ICD insertion complications, as well as demonstrating the normal appearances of the most frequently implanted devices.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.crad.2004.01.009 | DOI Listing |
ASAIO J
January 2025
From the Division of Cardiac Surgery, Department of Surgery, Johns Hopkins University School of Medicine, Baltimore, Maryland.
The use of cardiac devices, including mechanical circulatory support (MCS), cardiac implantable electronic devices (CIEDs), and pacing wires, has increased and significantly improved survival in patients with severe cardiac failure. However, these devices are frequently associated with acute brain injuries (ABIs) including ischemic strokes, intracranial hemorrhages, seizures, and hypoxic-ischemic brain injury which contribute substantially to morbidity and mortality. Computed tomography (CT) and magnetic resonance imaging (MRI), the standard imaging modalities for ABI diagnosis, can pose significant challenges in this patient population due to the risks associated with patient transportation and the incompatibility of ferromagnetic components of certain cardiac devices with high magnetic field of the MRI.
View Article and Find Full Text PDFJ Sports Sci
January 2025
Diabetes Research Centre, University of Leicester, Leicester, UK.
Acute studies have consistently demonstrated small-to-medium glycaemic responses to breaking prolonged sitting, yet it is not known whether acute effects are maintained following a period of intervention or whether behavioural interventions lead to sustained benefits. A single arm, 4-week intervention with pre and post "two-arm" randomised cross-over conditions, study was conducted to investigate whether reducing prolonged sitting in free-living affects acute and chronic glucose and insulin responses. Adults aged 40-75 years living with overweight or obesity with an elevated HbA1c (5.
View Article and Find Full Text PDFFront Cardiovasc Med
January 2025
Department of Cardiology, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, China.
Aims: This retrospective cohort study aimed to investigate the efficacy of dual-chamber left Bundle branch pacing (LBBP) as an alternative therapy for heart failure patients with complete left bundle branch block (CLBBB) and indications for defibrillator with cardiac resynchronization therapy (CRT-D).
Methods: 34 patients met inclusion criteria were enrolled in the study. These criteria included a left ventricular ejection fraction (LVEF) of lower than 35%, a New York Heart Association functional class of II-IV, CLBBB meeting Strauss's criteria, intraventricular dyssynchrony, and confirmed correction of CLBBB during LBBP.
JACC Clin Electrophysiol
January 2025
Cardioangiologisches Centrum Bethanien, Agaplesion Markus-Krankenhaus, Frankfurt am Main, Germany.
Background: The net benefit of oral anticoagulation in patients with end-stage renal disease on hemodialysis (HD) is uncertain. In recent years, left atrial appendage closure (LAAC) has emerged as an alternative to oral anticoagulation; however, there is scant evidence of LAAC in patients on HD.
Objectives: This study aimed to assess the feasibility and safety of LAAC in patients on HD.
JACC Clin Electrophysiol
January 2025
Department of Medicine and Research Center, Montreal Heart Institute and Université de Montréal, Montréal, Québec, Canada; Institute of Pharmacology, West German Heart and Vascular Center, University of Duisburg-Essen, Essen, Germany. Electronic address:
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!