The objective was to design a vascular phantom compatible with digital subtraction angiography, computerized tomography angiography, ultrasound and magnetic resonance angiography (MRA). Fiducial markers were implanted at precise known locations in the phantom to facilitate identification and orientation of plane views from three-dimensional (3-D) reconstructed images. A vascular conduit connected to tubing at the extremities of the phantom ran through an agar-based gel filling it. A vessel wall in latex was included around the conduit to avoid diffusion of contrast agents. Using a lost-material casting technique based on a low melting point metal, geometries of pathological vessels were modeled. During the experimental testing, fiducial markers were detectable in all modalities without distortion. No leak of gadolinium through the vascular wall was observed on MRA after 5 hours. Moreover, no significant deformation of the vascular conduit was noted during the fabrication process (confirmed by microtome slicing along the vessel). The potential use of the phantom for calibration, rescaling, and fusion of 3-D images obtained from the different modalities as well as its use for the evaluation of intra- and inter-modality comparative studies of imaging systems are discussed. In conclusion, the vascular phantom can allow accurate calibration of radiological imaging devices based on x-ray, magnetic resonance and ultrasound and quantitative comparisons of the geometric accuracy of the vessel lumen obtained with each of these methods on a given well defined 3-D geometry.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1118/1.1739300 | DOI Listing |
Front Public Health
January 2025
Bellvitge Biomedical Research Institute (IDIBELL), Hospitalet Barcelona, Barcelona, Spain.
Background And Purpose: The aim was to estimate the cost of the external beam radiotherapy (EBRT) in public health care centers in Catalonia (Spain), according to the ESTRO-HERO costing model for 2018.
Materials And Methods: Personnel, equipment, and activity data from 2018 from the 11 RT centers were used, incorporating European mean values adapted to the Catalan context. Secondly, EBRT costs were estimated, incorporating 2023 fractionation technique and scheme usage percentages.
Nat Commun
January 2025
Department of Chemistry, New York University, New York, NY, USA.
Advancements in cryo-EM have stimulated a revolution in structural biology. Yet, for membrane proteins near the cryo-EM size threshold of approximately 40 kDa, including transporters and G-protein coupled receptors, the absence of distinguishable structural features makes image alignment and structure determination a significant challenge. Furthermore, resolving more than one protein conformation within a sample, a major advantage of cryo-EM, represents an even greater degree of difficulty.
View Article and Find Full Text PDFRadiography (Lond)
December 2024
Newcastle Upon Tyne Hospitals NHS Foundation Trust, Northern Centre for Cancer Care, Newcastle Upon Tyne, United Kingdom; Newcastle University, Translational and Clinical Research Institute, Newcastle Upon Tyne, United Kingdom.
Purpose/objective: MR-only radiotherapy planning exploits the benefits of MRI soft-tissue delineation, whilst negating the registration inaccuracies caused by MRI CT fusion. Fiducial markers have conventionally been used in prostate radiotherapy to reduce on-treatment image matching variability. However, this is an invasive procedure for the patient, and presents technical difficulties in an MR-only pathway as fiducial markers are difficult to visualise on MRI.
View Article and Find Full Text PDFJ Struct Biol
December 2024
Biocomputing Unit, Centro Nacional de Biotecnologia (CNB-CSIC), Darwin, 3, Campus Universidad Autonoma, 28049 Cantoblanco, Madrid, Spain. Electronic address:
Cryo-electron tomography is an imaging technique that allows the study of the three-dimensional structure of a wide range of biological samples, from entire cellular environments to purified specimens. This technique collects a series of images from different views of the specimen by tilting the sample stage in the microscope. Subsequently, this information is combined into a three-dimensional reconstruction.
View Article and Find Full Text PDFGait Posture
December 2024
School of Biomedical Sciences and Pharmacy, College of Health, Medicine and Wellbeing, University of Newcastle, Callaghan, NSW 2308, Australia. Electronic address:
Background: Posture of the upper neck is considered by some to contribute to neck pain and headache. Infrared reflectors and cameras permit non-invasive three-dimensional (3D) evaluation of head and neck range of motion but have not been used to examine the relative pose (position and orientation) of the head, upper and lower neck.
Research Question: Can the relative 3D pose of the head, upper and lower neck regions of adult humans be non-invasively measured and perturbated while recording the characteristics of neck or head pain?
Methods: An optical motion capture system was used in a repeat measure descriptive analysis study.