Diplopia and periorbital mass associated with Miragel buckling explant.

Korean J Ophthalmol

The Institute of Vision Research and Department of Ophthalmology, College of Medicine, Yonsei University, Seoul, Korea.

Published: June 2004

A 28-year-old female presented with a palpable mass lesion on the superonasal aspect of her right globe and she had a progressive diplopia. She had a scleral encircling surgery with a Miragel explant (MIRA, Waltham, Mass, USA) for the tractional retinal detachment associated with pars planitis 9 years previously. On examination, she revealed restricted eye movements of her right eye. The magnetic resonance imaging documented a swelling of the Miragel explant that mimicked a periorbital mass lesion. The Miragel explant was removed and fragmentation of the explant was found intraoperatively. The removed Miragel explant was examined by a scanning electron microscopy, and this demonstrated a disintergrated and swollen structural composition of the Miragel explant. Postoperatively, her extraocular movement was almost restored and the retina remained well attached. Alterations in the structural composition of the Miragel explant results in an excessive swelling that causes a restriction of the extraocular movement, and this can mimick a periorbital mass lesion.

Download full-text PDF

Source
http://dx.doi.org/10.3341/kjo.2004.18.1.47DOI Listing

Publication Analysis

Top Keywords

miragel explant
24
periorbital mass
12
mass lesion
12
explant
8
structural composition
8
composition miragel
8
extraocular movement
8
miragel
7
mass
5
diplopia periorbital
4

Similar Publications

Hydrogel (Miragel®) scleral explant, late orbital complication.

Int J Surg Case Rep

September 2022

Family Medicine Department, King Abdulaziz Medical City, National Guard, Riyadh, Saudi Arabia.

Introduction: The hydrogel Scleral Buckle is a soft and pliable subtype of buckles which has been used to repair retinal breaks and detachments externally. This case represents an unusual late orbital complication of the implant.

Case Report: A 70 years old male patient presented with drooping right upper lid and eye misalignment, associated with foreign body sensation and discomfort.

View Article and Find Full Text PDF

Irreversible intraocular pressure elevation as a complication of MIRAgel scleral buckling.

Am J Ophthalmol Case Rep

September 2022

Department of Ophthalmology and Visual Science, Graduate School of Biomedical Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima City, Hiroshima, 734-8551, Japan.

Purpose: To report a case of ocular hypertension due to swelling and degeneration of hydrogel explant (MIRAgel) after retinal detachment surgery.

Observations: The patient who had a history of left retinal detachment 23 years prior had been regularly followed up for epiretinal membrane in the left eye at the Department of Ophthalmology, Hiroshima University Hospital. Two years after the first presentation, the patient had symptoms of foreign body sensation and hyperemia, with elevation of the intraocular pressure (IOP) of the left eye to 24 mmHg.

View Article and Find Full Text PDF

Background: MIRAgel (MIRA, Waltham, MA, USA) is a hydrogel scleral buckle introduced in 1979 to treat rhegmatogenous retinal detachments. Its use was discontinued because late complications that require surgical removal were reported.

Methods: Case report.

View Article and Find Full Text PDF

Purpose: To retrospectively report a case of complex retinal detachment secondary to an intraocular episcleral hydrogel explant (MIRAgel, MIRA Inc., Waltham, MA, USA) invasion.

Observations: The severe vitreous inflammation, shifting nature of the subretinal fluid, and absence of proliferative vitreopathy 2 months following multiple surgeries for removal of fragmented MIRA gel in the present case made the diagnosis of complex retinal detachment.

View Article and Find Full Text PDF

Optic nerve compression as a late complication of a hydrogel explant with silicone encircling band.

Am J Ophthalmol Case Rep

June 2018

Department of Ophthalmology, Radboud University Medical Center Nijmegen, Philips van Leydenlaan 15, 6525 EX Nijmegen, The Netherlands.

Purpose: To present a complication of compressive optic neuropathy caused by a swollen hydrogel explant and posteriorly displaced silicone encircling band.

Observations: A 72-year-old female patient presented with progressive visual loss and a tilted optic disc. Her medical history included a retinal detachment in 1993 that was treated with a hydrogel explant under a solid silicone encircling band.

View Article and Find Full Text PDF