Article Abstract

Background: Inferior subluxation of the proximal part of the fibula has been reported to occur with distraction osteogenesis of the tibia; however, the clinical sequelae of this subluxation are unknown. The purpose of this study was to evaluate inferior subluxation of the proximal part of the fibula and its possible clinical implications in patients who had undergone tibial lengthening by distraction osteogenesis with use of a unilateral external fixator.

Methods: Thirty tibiae in seventeen patients with a variety of conditions underwent tibial lengthening by distraction osteogenesis with use of a unilateral external fixator and were followed clinically and radiographically for a mean of two years and ten months (range, two to four years). Ten patients were female and seven were male. Their mean age at the time of the surgery was seventeen years (range, eight to twenty-five years). The mean tibial lengthening was 8.1 cm (range, 3.5 to 13 cm).

Results: An inferior shift of the fibular head in relation to the tibia was evident in all cases. The shift, which ranged from 0.4 to 3.3 cm, was proportionally related to the amount of tibial lengthening. This type of subluxation is probably attributable to the tension that is exerted by the intact interosseous membrane during the distraction as well as to the tension of the regenerated bone of the fibula and the fact that the fibula itself is not fixed or directly lengthened by the external fixator.

Conclusions: It appears that inferior subluxation of the fibula is a common phenomenon in patients undergoing tibial lengthening by distraction osteogenesis with use of a unilateral external fixator. However, no clinical symptoms or findings related to the inferior subluxation of the fibula were found in our series.

Download full-text PDF

Source
http://dx.doi.org/10.2106/00004623-200407000-00019DOI Listing

Publication Analysis

Top Keywords

tibial lengthening
24
inferior subluxation
20
unilateral external
16
distraction osteogenesis
16
external fixator
12
lengthening distraction
12
osteogenesis unilateral
12
fibular head
8
subluxation proximal
8
proximal fibula
8

Similar Publications

Multi-ligament reconstruction in adolescent patients affected by congenital femoral deficiency is an extremely rare and delicate surgical procedure. There are very few reported cases of complete anterior and posterior cruciate ligament agenesis in these patients. We present a complex case of a 16-year-old girl affected by congenital femoral deficiency and ipsilateral tibial hypoplasia who was treated successfully for a complete agenesis of the anterior (ACL) and posterior (PCL) cruciate ligament with single-sitting ACL and PCL reconstruction.

View Article and Find Full Text PDF

[Modified Z-plasty of the patellar tendon for patella baja and flexion deficits].

Oper Orthop Traumatol

January 2025

Klinik für Orthopädie und Unfallchirurgie, Martin-Luther-Krankenhaus Berlin, Caspar-Theyss-Str. 27-33, 14193, Berlin, Deutschland.

Objective: Lengthening of the patellar tendon to normalize patellar height and improve knee flexion deficits.

Indications: Flexion deficits in combination with patella baja (Caton index < 0.6).

View Article and Find Full Text PDF

Purpose: Previous studies have shown that subtrochanteric femoral fractures treated with intramedullary nails might lead to varus-procurvatum malalignment. Similar results have been reported when using antegrade intramedullary lengthening nails (ILNs). The purpose of our study is to examine if antegrade telescoping intramedullary lengthening nails lead to varus-procurvatum malalignment of the proximal femur and what are possible predictors of that shift.

View Article and Find Full Text PDF

Distraction osteogenesis is a valuable clinical technique used to address length discrepancies in long bone deformities. This procedure involves performing an osteotomy at an appropriate site in the bone and correcting the deformity through an extension system. This research aims to investigate the efficacy of a newly developed device for use in rat tibias and to provide an alternative to existing devices used in animal experiments.

View Article and Find Full Text PDF

Effect of human amniotic membrane on the consolidation during bone lengthening by distraction: Experimental study in rabbits.

J Orthop Sci

January 2025

Cell Therapy and Experimental Surgery of Musculoskeletal System LR18SP11 Lab, Faculty of Medicine, Sfax, Tunisia; Department of Orthopedics and Traumatology, CHU Habib Bourguiba, Sfax, Tunisia.

Objective: This study aimed to assess the effect of implantation of fresh human amniotic membranes (HAM) on bone consolidation during distraction bone lengthening.

Methods: Ten New Zealand white rabbits were used in this study. For each rabbit, we performed a diaphyseal tibial osteotomy after installing a single-plane distraction external fixator.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!