Study Design: This is a retrospective study conducted to evaluate the efficacy of single versus separate registration in assessing the pedicle screw accuracy in the computer-assisted lumbar spinal instrumentation.

Objectives: To see if separate registration reduced lumbar pedicle screw misplacement.

Summary Of Background Data: Computer-assisted spinal instrumentation has been shown to improve pedicle screw installation accuracy, but 2.7% to 8% of screws still perforate the pedicular cortex. Suspected causes include differences in lumbar lordosis between preoperative CT scans and surgery.

Methods: Postoperative radiographs and CT scans were used to assess the accuracy of pedicle screw placement in 47 adult patients following computer-assisted lumbar spinal instrumentation. Twenty-two patients underwent single registration at one level, while the other 25 underwent registration at each level.

Results: The time required for a registration procedure on one level was 6 to 8 minutes, while the time required for application of a pedicle screw using computer-assisted techniques was an additional 6 to 10 minutes. The total number of screw placements was 118 in the single registration group and 130 in the separate registration group. In the former group, 85 (72%) pedicle screw placements were categorized as good, 28 (24%) were fair, and 5 (4%) were poor. All five poorly placed screws were placed in the lower lumbar or upper sacral spine with high mobility, and at levels without registration, with one causing root injury. In the latter group, 117 (90%) pedicle screw placements were good and 13 (10%) were fair. The difference in placement was found to be statistically significant (chi2, P = 0.0003). CONCLUSION.: Before the intraoperative real-time CT imaging is widely used, separate registration at each instrumented level during traditional computer-assisted lumbar spinal instrumentation is necessary to enhance the accuracy of screw placement.

Download full-text PDF

Source
http://dx.doi.org/10.1097/01.brs.0000131438.68071.6cDOI Listing

Publication Analysis

Top Keywords

pedicle screw
32
separate registration
20
computer-assisted lumbar
16
screw placement
12
lumbar spinal
12
spinal instrumentation
12
screw placements
12
registration
10
screw
10
single versus
8

Similar Publications

Background: With the widespread use of lumbar pedicle screws for internal fixation, the morphology of the screws and the surrounding tissues should be evaluated. The metal artifact reduction (MAR) technique can reduce the artifacts caused by pedicle screws, improve the quality of computed tomography (CT) images after pedicle fixation, and provide more imaging information to the clinic.

Purpose: To explore whether the MAR+ method, a projection-based algorithm for correcting metal artifacts through multiple iterative operations, can reduce metal artifacts and have an impact on the structure of the surrounding metal.

View Article and Find Full Text PDF

A patient in his early adolescence, who was treated for T5-T6 tubercular spondylodiscitis with an un-instrumented decompression, presented at 36 months post-index surgery, for post-laminectomy instability and kyphosis, after completing his requisite antitubercular treatment. He underwent thoracic posterior instrumented kyphosis correction and anterior reconstruction, with a T5-T6 partial corpectomy and corpectomy spacer placement, through a posterior midline incision. On the second postoperative day, he started complaining of pain on the left side of his chest, abdomen and left shoulder.

View Article and Find Full Text PDF

Background: Pedicle screw insertion in posterior spinal surgery can cause vascular injuries, including rare intercostal artery pseudoaneurysms, which are typically discovered incidentally during reimaging. Onyx embolization is an effective treatment for small artery pseudoaneurysms.

Observations: A 36-year-old man who had initially presented with back pain that remained unresponsive to nonsteroidal anti-inflammatory drugs was diagnosed with a T7-8 sarcomatous lesion confirmed by magnetic resonance imaging and biopsy.

View Article and Find Full Text PDF

Background: Recent advances within the last decade have allowed robotics to become commonplace in the operating room. In the field of neurosurgery, robotics assist surgeons in pedicle screw placement and vertebral fusion procedures. The purpose of this review is to look at currently used spinal robots available on the market and compare their overall accuracy, cost, radiation exposure, general adverse events, and hospital readmission rates.

View Article and Find Full Text PDF

Preserving Cervical Mobility: A Novel Robot-Assisted Approach for Atlas Fracture Fixation.

Am J Case Rep

January 2025

Department of Orthopedic Surgery, Sichuan Provincial People's Hospital, School of Medicine, University of Electronic Science and Technology of China, Chengdu, Sichuan, China.

BACKGROUND The management of unstable atlas fractures remains a subject of ongoing debate and controversy. The conservative surgical treatment commonly involves fusion, resulting in severe loss of cervical spine mobility, and a large incisions and extensive tissue dissection are required. We aim to introduce a novel concept and surgical approach for treating atlas fracture, one that involves minimizing trauma while maintaining mobility of the upper cervical spine without resorting to fusion.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!