A newly developed severe acute respiratory syndrome (SARS)-specific enzyme-linked immunosorbent assay (ELISA) was further validated to confirm cutoff values and evaluate its diagnostic performance with clinical samples. In parallel, an immunochromatographic test was also evaluated. A total of 227 clinical serum specimens collected from SARS patients were used in the study, together with 385 samples from healthy donors. By use of an immunofluorescent (IF) test as the "gold standard", both the ELISA and the immunochromatographic test were able to detect immunoglobulin G antibodies to SARS not only from late-convalescent-stage samples (>21 days from the onset of clinical symptoms), as previously established, but also from early-acute-phase samples (1 to 10 days from onset). The ELISA, using an optical density (OD) of 0.25 as its cutoff value, produced the best sensitivity while maintaining high specificity. It detected SARS-specific antibodies in 58, 70, 75, and 95%, respectively, of the four groups of samples collected from patients 1 to 10 days, 11 to 20 days, 21 to 30 days, and more than 30 days after the onset of clinical symptoms. Similarly, the immunochromatographic test detected SARS-specific antibodies in 55, 68, 81, and 79% of the four groups, respectively. The overall specificities for the ELISA and the rapid test were 99.5 and 97.7%, respectively. Although the positive correlation observed between the ELISA OD values and the IF titers was moderate (r = 0.6915; P < 0.001), the detection rates of both the ELISA and the rapid test were found well in agreement with the IF titers.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC440612 | PMC |
http://dx.doi.org/10.1128/CDLI.11.4.699-703.2004 | DOI Listing |
Klin Mikrobiol Infekc Lek
March 2024
Institute of Microbiology, Faculty of Medicine, Palacky University in Olomouc, Czech Repubic, e-mail:
Objective: This study aimed to evaluate the occurrence of methicillin-resistant Staphylococcus aureus (MRSA) at the University Hospital Olomouc (UHO) over a 10-year period (2013-2022).
Material And Methods: Data was obtained from the ENVIS LIMS laboratory information system (DS Soft, Czech Republic, Olomouc) of the Department of Microbiology, UHO, for the period 1/1/2013-31/12/2022. Standard microbiological procedures using the MALDI-TOF MS system (Biotyper Microflex, Bruker Daltonics) were applied for the identification.
Adv Sci (Weinh)
January 2025
Department of Clinical Laboratory Medicine, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, Guangdong, 510000, China.
Immunochromatographic assays (ICAs) provide simple and rapid strategies for bacterial diagnosis but still suffer from the problems of low sensitivity and high dependency on paired antibodies. Herein, the broad-spectrum capture and detection capability of the antibody-free electropositive nanoprobe are clarified for bacteria for the first time and an ultrasensitive fluorescent ICA platform is constructed for the simultaneous diagnosis of multiple pathogens. A magnetic multilayer quantum dot nanocomposite with an amino-embedded SiO shell (MagMQD@Si) is designed to enrich bacteria from solutions effectively, offer high luminescence, and reduce background signals on test strips, thus greatly improving the sensitivity and stability of ICA technique for pathogen.
View Article and Find Full Text PDFAnal Methods
January 2025
Otolaryngology, Head and Neck Surgery Department of Fujian Provincial Hospital, Provincial Clinical Medical College of Fujian Medical University, Fuzhou University Affiliated Provincial Hospital, Fuzhou, Fujian, 35001, China.
Pepsin serves as a potential biomarker for laryngopharyngeal reflux disease (LPRD). The reported methods for detecting pepsin still have limitations, such as long reaction times and low sensitivity. Therefore, it is crucial to develop a rapid, simple and sensitive detection method.
View Article and Find Full Text PDFDis Aquat Organ
January 2025
National Pathogen Collection Center for Aquatic Animals, Shanghai Ocean University, 201306 Shanghai, PR China.
Cyvirus cyprinidallo 2 (CyHV-2) is the pathogen of herpesviral hematopoietic necrosis (HVHN) that mainly infects goldfish Carassius auratus and crucian carp C. carassius and is characterized by high infectivity and pathogenicity. The availability of rapid and convenient detection methods is essential for early detection of CyHV-2.
View Article and Find Full Text PDFMycopathologia
January 2025
Doodhadhari Burfani Hospital, Haridwar, Uttarakhand, India.
Background: LDBio immunochromatographic lateral flow assay, a point-of care test, detects IgM/IgG antibodies against Aspergillus fumigatus (LDBio-ALFA). LDBio-ALFA has been evaluated for diagnosing chronic pulmonary aspergillosis (CPA) in hospital patients, though its efficacy in field settings remains unexamined.
Objective: Our primary objective was to assess the diagnostic accuracy of LDBio-ALFA in diagnosing CPA in a field and a hospital cohort.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!