Results of the analyses of occupational and environmental samples are frequently reported as "less than a specified value," a practice followed by many analytical laboratories. A left-censored distribution occurs when analytical laboratories do not report results that fall below their limits of detection or quantification. Approximately 37% of the household interior dust lead loadings collected in a large-scale, multisite, longitudinal study of lead-based paint hazard controls were reported to be below the "method detection limit." These unreported values are unusable in any statistical analysis of the data and must be replaced by a valid dust lead loading estimate, a process called data imputation. This investigation tested how well data imputed using a newly formulated procedure for estimating the data below the method detection limit were correlated with dust lead loadings reported by the participating laboratories after special request. These results were also compared with those obtained by imputing the minimum detectable level by the square root of 2. Imputation of the low lead loadings was accomplished by substituting the value associated with the median percentile below each laboratory's method detection limit. A correlation of r = 0.50 was calculated between the predicted and reported dust lead loadings, with only slight bias (2.9%) in the predicted values. An alternative imputation procedure that used the predicted value from structural equation models fit to the noncensored dust lead loadings performed about as well, although the predictions had to be "centered" to correspond to the censored data. An estimator that combined both of these imputation procedures only slightly improved the correlation between the predicted and laboratory values (r = 0.51). These results support the use of the new procedure rather than the commonly used imputed values of the method detection limit divided by 2 or by the square root of 2. Imputing values based on either of these common approaches may result in much more biased predictions for the censored data; in the case of these data, the dust lead loadings were overestimated by 348%. The results also suggest that analytical laboratories should provide a numerical result for all analyzed samples, with a "flag" of those values below their detection limit, since these results may be more accurate than any imputed value, particularly those provided by the commonly used method of dividing the minimum detection limit by the square root of 2.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1080/15459620490462797 | DOI Listing |
Sci Rep
January 2025
Faculty of Art and Science, Department of Chemistry, Yıldız Technical University, 34220, İstanbul, Türkiye.
In the present study, dispersive solid phase extraction - hydride generation integrated with micro-sampling gas-liquid separator - flame atomic absorption spectrometry was proposed to determine lead in lake water samples taken in the Horseshoe Island, Antarctica. In scope of this study, microwave assisted NiFeO nanoparticles were synthesized, and the characterization of nanoparticles were carried out by FT-IR, XRD and SEM. All influential parameters of dispersive solid phase extraction and hydride generation were optimized to enhance signal intensity belonging to the analyte.
View Article and Find Full Text PDFMikrochim Acta
January 2025
Department of Analytical Chemistry, Faculty of Pharmacy, "Iuliu Hațieganu" University of Medicine and Pharmacy, 4 Pasteur Street, 400349, Cluj-Napoca, Romania.
A label-free, flexible, and disposable aptasensor was designed for the rapid on-site detection of vancomycin (VAN) levels. The electrochemical sensor was based on lab-printed carbon electrodes (C-PE) enriched with cauliflower-shaped gold nanostructures (AuNSs), on which VAN-specific aptamers were immobilized as biorecognition elements and short-chain thiols as blocking agents. The AuNSs, characterized by scanning electron microscopy (SEM) and atomic force microscopy (AFM), enhanced the electrochemical properties of the platform and the aptamer immobilization active sites.
View Article and Find Full Text PDFHematol Transfus Cell Ther
November 2024
Hospital São Rafael, Salvador, Bahia, Brazil; Instituto D'Or de Pesquisa e Ensino (IDOR), Salvador, Bahia, Brazil; Instituto Gonçalo Moniz, FIOCRUZ, Salvador, Bahia, Brazil. Electronic address:
Mesenchymal stromal cells are multipotent cells present in various tissues that are widely studied for relevant therapeutic potential due to their paracrine immunomodulatory and tissue regenerating properties. Many mesenchymal stromal cell-based products are under investigation for the treatment of different clinical conditions. Recently, the therapeutic potential of the extracellular vesicles released by these cells has been under focus, with emphasis on clinical translation.
View Article and Find Full Text PDFAnal Chim Acta
February 2025
Engineering Research Center of Optical Instrument and System, Ministry of Education and Shanghai Key Lab of Modern Optical System, University of Shanghai for Science and Technology, No.516 Jungong Road, Shanghai, 200093, China.
Background: Surface-enhanced Raman scattering (SERS) has attracted much attention as a powerful detection and analysis tool with high sensitivity and fast detection speed. The intensity of the SERS signal mainly depended on the highly enhanced electromagnetic field of nanostructure near the substrate. However, the fabrication of high-quality SERS nanostructured substrates is usually complicated, makes many methods unsuitable for large-scale production of SERS substrates.
View Article and Find Full Text PDFAnal Chim Acta
February 2025
Food Inspection and Quarantine Technology Center of Shenzhen Customs, Shenzhen Academy of Inspection and Quarantine, Shenzhen, 518045, PR China.
Background: Ochratoxin A (OTA) is toxic secondary metabolites produced by fungi and can pose a serious threat to food safety and human health. Due to the high stability and toxicity, OTA contamination in agricultural products is of great concern. Therefore, the development of a highly sensitive and reliable OTA detection method is crucial to ensure food safety.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!