Parameter optimization of pulse compression in ultrasound imaging systems with coded excitation.

Ultrasonics

Department of Biomedical Engineering, Technion--Israel Institute of Technology, Technion City, Haifa 32000.

Published: August 2004

A linear array imaging system with coded excitation is considered, where the proposed excitation/compression scheme maximizes the signal-to-noise ratio (SNR) and minimizes sidelobes at the output of the compression filter. A pulse with linear frequency modulation (LFM) is used for coded excitation. The excitation/compression scheme is based on the fast digital mismatched filtering. The parameter optimization of the excitation/compression scheme includes (i) choice of an optimal filtering function for the mismatched filtering; (ii) choice of an optimal window function for tapering of the chirp amplitude; (iii) optimization of a chirp-to-transducer bandwidth ratio; (iv) choice of an appropriate n-bit quantizer. The simulation results show that the excitation/compression scheme can be implemented as a Dolph-Chebyshev filter including amplitude tapering of the chirp with a Lanczos window. An example of such an optimized system is given where the chirp bandwidth is chosen to be 2.5 times the transducer bandwidth and equals 6 MHz: The sidelobes are suppressed to -80 dB, for a central frequency of 4 MHz, and to -94 dB, for a central frequency of 8 MHz. The corresponding improvement of the SNR is 18 and 21 dB, respectively, when compared to a conventional short pulse imaging system. Simulation of B-mode images demonstrates the advantage of coded excitation systems of detecting regions with low contrast.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultras.2004.02.020DOI Listing

Publication Analysis

Top Keywords

coded excitation
16
excitation/compression scheme
16
parameter optimization
8
imaging system
8
mismatched filtering
8
choice optimal
8
tapering chirp
8
central frequency
8
frequency mhz
8
optimization pulse
4

Similar Publications

Photic drive response in people with epilepsy: Exploring the interaction with background alpha rhythm.

Vision Res

January 2025

Eccles Institute of Neuroscience, John Curtin School of Medical Research, Australian National University, Acton, ACT, Australia. Electronic address:

Photic drive responses (PDRs) are used to explore cortical hyperexcitability. We quantified PDRs and interactions with the alpha rhythm in people with epilepsy (PwE). Fifteen PwE (mean age ± SD 47.

View Article and Find Full Text PDF

Monolithic Multiparameter Terahertz Nano/Microdetector Based on Plasmon Polariton Atomic Cavity.

Adv Mater

January 2025

State Key Laboratory of Optoelectronic Materials and Technologies, Guangdong Province Key Laboratory of Display Material and Technology, School of Electronics and Information Technology, Sun Yat-sen University, Guangzhou, 510275, China.

Terahertz (THz) signals are crucial for ultrawideband communication and high-resolution radar, demanding miniaturized detectors that can simultaneously measure multiple parameters such as intensity, frequency, polarization, and phase. Traditional detectors fail to meet these needs. To address this, we introduce a plasmon polariton atomic cavity (PPAC) detector based on monolayer graphene, offering a multifunctional, monolithic, and miniaturized solution.

View Article and Find Full Text PDF

With the advent of the 5G era, high-precision localization based on mobile communication networks has become a research hotspot, playing an important role in indoor emergency rescue in shopping malls, smart factory management and tracking, as well as precision marketing. However, in complex environments, non-line-of-sight (NLOS) propagation reduces the measurement accuracy of 5G signals, causing large deviations in position solving. In order to obtain high-precision position information, it is necessary to recognize the propagation state of the signal before distance measurement or angle measurement.

View Article and Find Full Text PDF

Oral cancer ranks among the top ten cancers globally, with a five-year survival rate below 50%. This study aimed to evaluate the effectiveness of autofluorescence-guided surgery compared to standard surgical methods in identifying tumor-free margins and ensuring complete excision. A prospective cohort of 80 patients was randomized into two groups: the control group underwent excision with a 10 mm margin based on clinical judgment, while the experimental group used autofluorescence guidance with a 5 mm margin beyond fluorescence visualization loss.

View Article and Find Full Text PDF

Aging leads to cognitive decline and increased risk of neurodegenerative diseases. While molecular changes in central nervous system (CNS) cells contribute to this decline, the mechanisms are not fully understood. Long non-coding RNAs (lncRNAs) are key regulators of cellular functions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!