Evaluation of a new modulus mapping technique to investigate microstructural features of human teeth.

J Biomech

Department of Preventive and Restorative Dental Sciences, University of California, San Francisco, Box 0758, D 2260 San Francisco, CA 94143-0758, USA.

Published: August 2004

Teeth contain several calcified tissues with junctions that provide interfaces between dissimilar tissues. These junctions have been difficult to characterize because of their small size. In this work a new technique using a combination of atomic force microscopy (AFM) and a force-displacement transducer was used to simultaneously study the surface topography and map mechanical properties of the junctions and adjacent hard tissues. Prepared specimens from human third molars were scanned by an AFM piezo-tube in contact mode. To measure the dynamic viscoelastic properties of the material a small sinusoidal force was superimposed on the contact force and the resulting displacement amplitude and the phase shift between the force and amplitude were measured. This force modulation technique was used to map the local variation of nanomechanical properties of intertubular dentin, peritubular dentin, enamel, dentin-enamel junction (DEJ) and peritubular-intertubular dentin junction (PIJ). This new technique allowed us to measure the widths of these junctions in addition to local variation in dentin and enamel without causing plastic deformation to the material and with 2 orders of magnitude increase in spatial resolution compared with previous studies that used discrete nanoindentation techniques. Due to the ability to analyze the sample line-by-line, the distribution functions associated with the width of the DEJ and PIJ were conveniently obtained for specific intratooth locations. The data suggested, for three third molar specimens, a DEJ width of 2-3 microm with full-width half-maximum (FWHM) of 0.7 microm and PIJ width of 0.5-1.0 microm with 0.3 microm FWHM. The intertubular dentin storage modulus variation was between 17 and 23 GPa with a mean value of 21 GPa. The range of storage modulus for enamel near the DEJ was between 51 and 74 GPa with a mean value of 63 GPa.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jbiomech.2003.12.012DOI Listing

Publication Analysis

Top Keywords

tissues junctions
8
local variation
8
intertubular dentin
8
dentin enamel
8
storage modulus
8
gpa gpa
8
force
5
dentin
5
evaluation modulus
4
modulus mapping
4

Similar Publications

Cardiomyocyte-specific long noncoding RNA Trdn-as induces mitochondrial calcium overload by promoting the mA modification of calsequestrin 2 in diabetic cardiomyopathy.

Front Med

January 2025

Department of Pharmacology (SKLFZCD, State Key Laboratory-Province Key Laboratories of Biomedicine-Pharmaceutics of China, Key Laboratory of Cardiovascular Research, Ministry of Education), College of Pharmacy, Harbin, 150081, China.

Diabetic cardiomyopathy (DCM) is a medical condition characterized by cardiac remodeling and dysfunction in individuals with diabetes mellitus. Sarcoplasmic reticulum (SR) and mitochondrial Ca overload in cardiomyocytes have been recognized as biological hallmarks in DCM; however, the specific factors underlying these abnormalities remain largely unknown. In this study, we aimed to investigate the role of a cardiac-specific long noncoding RNA, D830005E20Rik (Trdn-as), in DCM.

View Article and Find Full Text PDF

Efficacy of urethral suspension-assisted urethral anastomosis as a treatment for complex long-segment posterior urethral stricture.

World J Urol

January 2025

Department of Urology, Shanghai Sixth People's Hospital, Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai Eastern Institute of Urologic Reconstruction, Shanghai, 200233, China.

Purpose: To determine the clinical effects of urethral suspension-assisted urethral anastomosis on complex long-segment posterior urethral stricture and describe the technical aspects of this procedure.

Materials And Methods: The clinical data for 24 patients who underwent urethral suspension-assisted urethral anastomosis for complex long-segment posterior urethral stricture between March 2021 and March 2024 were retrospectively analyzed. The surgical procedure comprises the following four steps: creation of an inverted Y-shaped incision in the perineum; mobilization of the urethra up to the penile-scrotal junction followed by dissection and separation of the septum of the corpus cavernosum; separation of the inferior pubic symphysis, excising a portion of the inferior pubic symphysis bone tissue and thoroughly clearing the scar tissue surrounding the proximal urethra; and suturing and suspension of the proximal urethra and surrounding tissues at the 2, 5, 7, and 10 o'clock positions, ensuring complete exposure of the proximal urethral mucosa and tension-free anastomosis between the proximal and distal urethra.

View Article and Find Full Text PDF

E-Cadherin-Mediated Cell-Cell Adhesion and Invasive Lobular Breast Cancer.

Adv Exp Med Biol

January 2025

Cancer Research UK Scotland Centre (Edinburgh), Institute of Genetics & Cancer, University of Edinburgh, Edinburgh, UK.

E-cadherin is a transmembrane protein and central component of adherens junctions (AJs). The extracellular domain of E-cadherin forms homotypic interactions with E-cadherin on adjacent cells, facilitating the formation of cell-cell adhesions, known as AJs, between neighbouring cells. The intracellular domain of E-cadherin interacts with α-, β- and p120-catenins, linking the AJs to the actin cytoskeleton.

View Article and Find Full Text PDF

Background: The main challenge in new drug development is accurately predicting the human response in preclinical models.

Methods: In this study, we developed three different intestinal barrier models using advanced biofabrication techniques: (i) a manual model containing Caco-2 and HT-29 cells on a collagen bed, (ii) a manual model with a Caco-2/HT-29 layer on a HDFn-laden collagen layer, and (iii) a 3D bioprinted model incorporating both cellular layers. Each model was rigorously tested for its ability to simulate a functional intestinal membrane.

View Article and Find Full Text PDF

Cold atmospheric plasma (CAP) has been utilized in various medical devices using its oxidative nature. Recent studies have provided evidence that CAP can facilitate the delivery of large, hydrophilic molecules through the epidermis to the dermis. On the other hand, a new approach called low-intensity CAP (LICAP) has been developed, allowing the plasma level to be controlled within a subtoxic range, thereby demonstrating various biological benefits without tissue damage.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!