OBJECTIVE--The feasibility of color Doppler tissue velocity imaging (c-TVI) with a high time resolution of 10 ms for simultaneous measurement of the temporal characteristics of regional left ventricular (LV) tissue velocities at different LV sites was examined. Methods and results--In 20 subjects with structurally normal hearts, inter- and intraobserver agreement and the beat-to-beat variation were tested in c-TVI profiles from basal and mid-LV segments of the interventricular septum (IS) and of the lateral free wall (LFW). For peak tissue velocities a mean error of less than 1 cm/s was demonstrated. For systolic regional LV velocity time difference, the mean error was +/- 5 ms, with the best agreement when sampling from basal LV sites. For diastolic regional LV velocity time differences, the mean error was +/- 12 ms. The longitudinal LV movement pattern demonstrated a pattern of incremental tissue velocity from basal to mid-LV, and from IS to LFW sites. Conclusion--The c-TVI method has acceptable inter- and intraobserver agreement and is sufficiently accurate to disclose regional time aspects of LV contraction and relaxation.

Download full-text PDF

Source
http://dx.doi.org/10.1080/14017430310016180DOI Listing

Publication Analysis

Top Keywords

tissue velocity
12
feasibility color
8
color doppler
8
doppler tissue
8
velocity imaging
8
left ventricular
8
longitudinal movement
8
tissue velocities
8
inter- intraobserver
8
intraobserver agreement
8

Similar Publications

Background: This study investigated the influence of surgical alignment techniques on knee joint biomechanics during stair negotiation tasks. Our hypothesis was that a more personalized joint alignment would result in reduced medial knee loading biomechanics to negotiate the stairs.

Methods: There were 28 adults (14 mechanical alignments [MA], 14 kinematic alignment [KA]) who underwent total knee arthroplasty (TKA) at least one year post-operatively and performed five stair ascent and descent trials at their preferred velocities.

View Article and Find Full Text PDF

Microneedle(MN)-based drug delivery is one of the potential approaches to overcome the limitations of oral and hypodermic needle delivery. An in silico model has been developed for hollow microneedle (HMN)-based drug delivery in the skin and its subsequent absorption in the blood and tissue compartments in the presence of interstitial flow. The drug's reversible specific saturable binding to its receptors and the kinetics of reversible absorption across the blood and tissue compartments have been taken into account.

View Article and Find Full Text PDF

Objective: The triply periodic minimal surface (TPMS) Gyroid porous scaffolds were built with identical porosity while varying pore sizes were used by fluid mechanics finite element analysis (FEA) to simulate the microenvironment. The effects of scaffolds with different pore sizes on cell adhesion, proliferation, and osteogenic differentiation were evaluated through calculating fluid velocity, wall shear stress, and permeability in the scaffolds.

Methods: Three types of gyroid porous scaffolds, with pore sizes of 400, 600 and 800 μm, were established by nTopology software.

View Article and Find Full Text PDF

Effect of bar jump height on kinetics and kinematics of take-off in agility dogs.

PLoS One

January 2025

Faculty of Veterinary Medicine, Department of Equine and Small Animal Medicine, University of Helsinki, Helsinki, Finland.

Sport-related injuries have been reported to occur in around one-third of agility dogs. Higher bar height in competitions has been shown to increase odds of an injury. This study evaluated the effect of bar height on the kinetics and kinematics at take-off to a bar jump.

View Article and Find Full Text PDF

Reduce electrical overload via threaded Chinese acupuncture in nerve electrical therapy.

Bioact Mater

April 2025

Department of Orthopaedics, Shanghai Key Laboratory for Prevention and Treatment of Bone and Joint Diseases, Shanghai Institute of Traumatology and Orthopaedics, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, 197 Ruijin 2nd Road, Shanghai, 200025, PR China.

Bioelectrical stimulation is a powerful technique used to promote tissue regeneration, but it can be hindered by an "electrical overload" phenomenon in the core region of stimulation. We develop a threaded microneedle electrode system that protects against "electrical overload" by delivering medicinal hydrogel microspheres into the core regions. The threaded needle body is coated with polydopamine and chitosan to enhance the adhesion of microspheres, which are loaded into the threaded grooves, allowing for their stereoscopic release in the core regions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!