A novel physiological cardiac assist device (PCAD), otherwise known as the LEVRAM assist device, which is synchronized with the heartbeat, was developed to assist the left ventricle (LV) in chronic heart failure (CHF). The PCAD utilizes a single cannula, which is inserted in less than 15 s through the apex of the beating LV by means of a specially designed device. Blood is withdrawn from the LV into the PCAD in diastole and is injected back to the LV, through the same cannula, during the systolic ejection phase, thereby augmenting stroke volume (SV) and stroke work (SW). CHF with dilated LV was induced in sheep by successive intracoronary injections of 100-microm beads. The sheep (92.2 +/- 25.9 kg, n = 5) developed stable CHF with increased LV end-diastolic diameter (69.4 +/- 3.3 mm) and end-diastolic volume (LVEDV = 239 +/- 32 mL), with severely reduced ejection fraction (23.8 +/- 7.6%), as well as mild-to-moderate mitral regurgitation. The sheep were anesthetized, and the heart was exposed by left thoracotomy. Pressure was measured in the LV and aorta (Millar). The SV was measured by flow meters and the LV volume by sonocrystals. Assist was provided every 10 regular beats, and the assisted beats were compared with the preceding unassisted beats, at the same LVEDV. The PCAD displaced 13.6 +/- 3.4 mL, less than 8% of LVEDV. Added SW was calculated from the assisted and control pressure-volume loops. The efficiency, defined as an increase in SW divided by the mechanical work of the PCAD, was 85.4 +/- 16.9%. We conclude that the PCAD, working with a small displaced blood volume in synchrony with the heartbeat, efficiently augments the SW of the dilated failing LV. The PCAD is suggested for use as a permanent implantable device in CHF.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1196/annals.1302.033 | DOI Listing |
ASAIO J
January 2025
Division of Cardiovascular Medicine, Department of Medicine, Stanford University School of Medicine, Palo Alto, California.
The use of an alteplase (Activase) purge solution to address Impella ventricular assist device "thrombosis" or "purge system occlusion" has been mainly documented with earlier generation Impella devices (CP, 2.5, 5.0).
View Article and Find Full Text PDFOral Maxillofac Surg
January 2025
Department of Oral and Maxillofacial Diseases, Helsinki University and Helsinki University Hospital, Helsinki, Finland.
Purpose: Preoperative virtual planning and osteosynthesis with patient-specific implants (PSIs) have become a quotidian approach to many maxillofacial elective surgery setups. When a process is well-organized, a similar approach can be harnessed to serve the needs of exact primary reconstructions, especially in midfacial trauma cases. PSI osteosynthesis of the mandible is, however, more challenging because a mirror technique of the facial sides is often unreliable due to inherent lack of symmetry, and movement of the mandible increases the risk of loosening of the osteosynthesis.
View Article and Find Full Text PDFACS Appl Mater Interfaces
January 2025
Centre for Organic Photonics & Electronics, School of Chemistry and Molecular Biosciences, The University of Queensland, Brisbane, Queensland 4072, Australia.
The power conversion efficiency (PCE) of perovskite solar cells is sensitive to their method of fabrication as well as the combination of materials in the perovskite layer. Air knife-assisted blade coating enables good quality perovskite films to be formed but the device efficiencies still tend to lag behind those fabricated using spin-coated perovskite layers. Herein we report the use of three 2,3,4,5,6-pentafluorophenylethylammonium halides (FEAX, where X = I, Br or Cl) as additives in nitrogen knife-assisted blade-coated methylammonium lead iodide (MAPbI) perovskite solar cells.
View Article and Find Full Text PDFVet Sci
January 2025
Programa de Pós-Graduação em Ciências Veterinárias, Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre 91540-000, Brazil.
Pregnant ewes are susceptible to hypoglycemia and ketosis; therefore, monitoring glycemic status is extremely important. Portable blood glucose meters (PBGMs) can assist in quickly and conveniently identifying glycemic disturbances in this species, provided that they meet the criteria of analytical accuracy. This study evaluated the performance of a human PBGM (Accu-Chek Performa, Roche Diagnostics, Basel, Switzerland) in the glycemic evaluation of 34 pregnant ewes at days 90 and 120 of pregnancy in comparison with the results of glycemia determination by a reference method (RM).
View Article and Find Full Text PDFBiosensors (Basel)
January 2025
State Key Laboratory of Radio Frequency Heterogeneous Integration (Shenzhen University), Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China.
Fluorescence lifetime imaging (FLIM) has established itself as a pivotal tool for investigating biological processes within living cells. However, the extensive imaging duration necessary to accumulate sufficient photons for accurate fluorescence lifetime calculations poses a significant obstacle to achieving high-resolution monitoring of cellular dynamics. In this study, we introduce an image reconstruction method based on the edge-preserving interpolation method (EPIM), which transforms rapidly acquired low-resolution FLIM data into high-pixel images, thereby eliminating the need for extended acquisition times.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!