Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The purpose of this research was to investigate the interaction of water with ethylcellulose samples and assess the effect of particle size on the interaction. The distribution of water within coarse particle ethylcellulose (CPEC; average particle size 310 micro m) and fine particle ethylcellulose (FPEC; average particle size 9.7 micro m) of 7 cps viscosity grade was assessed by differential scanning calorimetry (DSC) and dynamic vapor sorption analysis. The amounts of nonfreezing and freezing water in hydrated samples were determined from melting endotherms obtained by DSC. An increase in water content resulted in an increase in the enthalpy of fusion of water for the two particle size fractions of EC. The amount of nonfreezable water was not affected by the change in particle size at low water contents. Exposure of ethylcellulose to water for 30 minutes is sufficient to achieve equilibration within the hydrated polymer at 47% wt/wt water content. The moisture sorption profiles were analyzed according to the Guggenheim-Anderson-de Boer (GAB) and Young and Nelson equations, which can help to distinguish moisture distribution in different physical forms. The amount of externally adsorbed moisture was greater in the case of FPEC. Internally absorbed moisture was evident only with the CPEC. In light of these results, an explanation is offered for the success of FPEC in wet-granulation methods where CPEC was not successful.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2750653 | PMC |
http://dx.doi.org/10.1208/pt040460 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!