Left ventricular (LV) and left atrial (LA) chamber sizes are frequently used to assist in assessing the severity of mitral regurgitation (MR). To study the reliability of these measurements in the clinical setting 2-dimensional echocardiographic measurements of the left ventricle and left atrium were obtained in 92 consecutive patients with MR present on both angiography and Doppler echocardiographic examinations performed within 2.8 +/- 2.5 days of each other. The accuracy of chamber dimensions in identifying severe MR (angiographic grade 3 to 4+) was determined in the total population and the following patient subgroups: (1) isolated chronic MR with preserved LV function inclusive of all rhythms; (2) isolated chronic MR, preserved LV function and sinus rhythm; (3) isolated chronic MR with LV dysfunction; (4) chronic MR associated with other valvular disease; and (5) acute MR. Only in subgroup 2 were chamber sizes reliable in identifying severe MR. Atrial dimensions provided the most accurate assessment with an LA volume greater than 58 ml, anteroposterior dimension greater than 45 mm and superoinferior dimension greater than 55 mm, with sensitivities of 75, 75 and 88%, specificities of 83, 100 and 83%, positive predictive values of 92, 100, and 93% and negative predictive values of 56, 60, and 71%, respectively. LV dimensions had excellent positive predictive values but lower sensitivities. Normalizing for body surface area did not improve the accuracy of uncorrected dimensions. Although increased LA and LV dimensions can identify severe MR, smaller dimensions do not exclude this diagnosis. With acute MR, atrial fibrillation, LV dysfunction or associated valvular disease, these dimensions are not reliable.

Download full-text PDF

Source
http://dx.doi.org/10.1016/0002-9149(92)90558-gDOI Listing

Publication Analysis

Top Keywords

chamber sizes
12
isolated chronic
12
predictive values
12
left atrial
8
left ventricular
8
severity mitral
8
mitral regurgitation
8
identifying severe
8
chronic preserved
8
preserved function
8

Similar Publications

Negative magnetophoresis is employed to levitate cells in a paramagnetic medium without the need for magnetic labeling, preserving their natural state and minimizing toxicity. The single-ring magnet configuration that provides an open space in the levitation chamber enhances culture accessibility and scalability, enabling the formation of millimeter-sized 3D structures through cellular self-assembly. This system provides a versatile and cost-effective approach for diverse applications, including tissue engineering and biofabrication.

View Article and Find Full Text PDF

DeSPPNet: A Multiscale Deep Learning Model for Cardiac Segmentation.

Diagnostics (Basel)

December 2024

Department of Electrical, Electronic and Systems Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, Bangi 43600, Malaysia.

Background: Cardiac magnetic resonance imaging (MRI) plays a crucial role in monitoring disease progression and evaluating the effectiveness of treatment interventions. Cardiac MRI allows medical practitioners to assess cardiac function accurately by providing comprehensive and quantitative information about the structure and function, hence making it an indispensable tool for monitoring the disease and treatment response. Deep learning-based segmentation enables the precise delineation of cardiac structures including the myocardium, right ventricle, and left ventricle.

View Article and Find Full Text PDF

Objective: Size at birth is a key indicator of in utero growth. Our objective was to generate sex-specific percentiles for birth weight and head circumference in neonates born between 22 and 29 weeks gestation from pregnancies without hypertension or diabetes and assess differences between vaginal and caesarean births and between singletons and twins.

Methods: We used data from 12 countries participating in the International Network for Evaluating Outcomes in Neonates database from 2007 to 2021.

View Article and Find Full Text PDF

On the correction factors for small field dosimetry in 1.5T MR-linacs.

Phys Med Biol

January 2025

Medical Physics Laboratory, School of Medicine, National and Kapodistrian University of Athens, 75 Mikras Asias, Goudi, Athens, Attica, 11527, GREECE.

Clinical dosimetry in the presence of a 1.5T magnetic field is challenging, let alone in case small fields are involved. The scope of this study is to determine a set of relevant correction factors for a variety of MR-compatible detectors with emphasis on small fields.

View Article and Find Full Text PDF

Aim: To study the dosimetric behavior of dose computational algorithms in inhomogeneous medium using CMS XiO and MONACO treatment planning system (TPS) for 4 megavoltage (MV), 6 MV and 15 MV photon beam energies.

Material And Methods: Styrofoam blocks of thickness 1.90 cm, 3.

View Article and Find Full Text PDF