Aim: The aim of the present study was to evaluate [123I] MIBG uptake and clearance in patients with hypertrophic cardiomyopathy (HCM) and to assess their relationships with left ventricular function (systolic and diastolic) and perfusion.

Methods: Eleven consecutive patients with HCM (8 men and 3 women; mean age 38+/-12 years, none in the dilated phase) underwent (in separate days, in random order) [123I]-MIBG scintigraphy, [(99m)Tc]-MIBI SPET at rest, and echocardiography. All patients were studied in fasting condition, and all medications were discontinued. [(99m)Tc]-MIBI SPET study was performed 1 hour after tracer injection. [123I]-MIBG study was acquired 5 minutes (planar) and 4 hours (planar and SPET) after the i.v. injection of [123I]-MIBG. Heart to mediastinum ratio (H/M) was computed at 4 hours. Wash out rate (WOR) was computed as: (H early - H delayed)/(H early), after decay correction. Both [123I]-MIBG and [(99m)Tc]-MIBI SPET were analyzed on 3 short axis views (apical, middle, and basal). Left ventricular outflow tract gradient (LVOTG), ejection fraction, volumes, septum thickness, and left atrial fractional shortening (LAFS) were evaluated on echocardiography.

Results: [123I]-MIBG WOR showed a positive relationship with LVOTG (r=0.84, p<0.001) and septum thickness (r=0.76, p<0.01), while a negative one was found with LAFS (r= -0.66, p<0.05). The study group was divided into: Group A (n=5) with higher, and Group B (n=6) with lower WOR than the median value (i.e. 11%). Group A patients had significantly lower LAFS (17.6+/-4.8 vs 26.8+/-7.2%, p<0.05), higher LVOTG (49+/-35 vs 3+/-3 mmHg), and thicker septum (21+/-2 vs 17+/-2 mm) than Group B patients. Inferior and septal wall [123I]-MIBG uptake on 4 hour SPET was significantly lower in Group A than in Group B. On the other hand, no differences were found in (99m)T-MIBI SPET rest regional uptake between the 2 subgroups of patients.

Conclusion: These results suggest that cardiac sympathetic activity correlates to cardiac anatomy (i.e. degree of hypertrophy) and diastolic function in patients with HCM.

Download full-text PDF

Source

Publication Analysis

Top Keywords

left ventricular
12
[99mtc]-mibi spet
12
patients hypertrophic
8
hypertrophic cardiomyopathy
8
injection [123i]-mibg
8
[123i]-mibg
6
sympathetic nervous
4
nervous function
4
patients
4
function patients
4

Similar Publications

The duration of mechanical systole-also termed the flow time (FT) or left ventricular ejection time (LVET)-is measured by Doppler ultrasound and increasingly used as a stroke volume (SV) surrogate to guide patient care. Nevertheless, confusion exists as to the determinants of FT and a critical evaluation of this measure is needed. Using Doppler ultrasound of the left ventricular outflow tract velocity time integral (LVOT VTI) as well as strain and strain rate echocardiography as grounding principles, this brief commentary offers a model for the independent influences of FT.

View Article and Find Full Text PDF

Left ventricular rigor mortis interferes with postmortem aortic root geometry.

Int J Legal Med

January 2025

Institute for Legal Medicine, Faculty of Medicine, Saarland University, Campus Homburg, Building 49.1, Kirrberger Straße 100, 66421, Homburg/Saar, Germany.

Aortic regurgitation is a common valve disease and can be caused by delineated findings such as fenestrations or hardly discernible alterations of the aortic root geometry. Therefore, aortic regurgitation can be a challenging diagnosis during an autopsy. Cardiac surgeons, however, are confronted with comparable problems during surgery and have developed a refined knowledge of the anatomy of the aortic root including its geometry.

View Article and Find Full Text PDF

Aims: Left ventricular (LV) diastolic dysfunction and heart failure with preserved ejection fraction (HFpEF) are common cardiac complications of patients with systemic sclerosis (SSc). Exercise stress echocardiography is often used in symptomatic patients with SSc to detect abnormal increases in pulmonary pressures during exercise, but the pathophysiologic and prognostic significance of exercise stress echocardiography to assess the presence of HFpEF in these patients is unclear.

Methods And Results: Patients with SSc (n=140) underwent ergometry exercise stress echocardiography with simultaneous expired gas analysis.

View Article and Find Full Text PDF

Background: GLP-1 RAs improve cardiometabolic outcomes in obese, diabetic, and heart failure patients. Data on the safety and efficacy of GLP-1 RA in advanced heart failure with durable LVAD is limited.

Objectives: To assess the safety and efficacy of GLP-1 RA in durable LVAD patients.

View Article and Find Full Text PDF

Pimobendan oral solution is bioequivalent to pimobendan chewable tablets in beagle dogs.

J Vet Intern Med

January 2025

Boehringer Ingelheim Pharma GmbH & Co., Ingelheim, Germany.

Background: Myxomatous mitral valve disease (MMVD) is frequently diagnosed in small breed dogs. Pimobendan oral solution has been developed to improve dosing accuracy in small and toy breed dogs.

Hypothesis/objectives: Demonstrate bioequivalence of pimobendan oral solution with pimobendan chewable tablets using a pharmacokinetic and a pharmacodynamic study in healthy purpose bred dogs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!