Measurements were performed on the 30, 40, and 60 mm 90Sr/Y beta-emitter source trains used in the Novoste Beta-Cath system to determine their dosimetric characteristics at submillimeter distances and provide the necessary TG-60 parameters for mapping their dose distributions. These measurements were carried out in a Solid Water phantom where MD55-2 Gafchromic films were placed in direct contact with a 5 French (F) catheter used for the 30 and 60 mm source trains and a 3.5F catheter used for thinner 30 and 40 mm source trains. A data set consisted of three pieces of Gafchromic film irradiated for periods of 1.5, 5, and 10 minutes, respectively. This 3-film irradiation technique provided reliable dose data at short, intermediate and long distances from a source train. Three data sets per source train were collected in this study. For the 30 mm source train with a 5F catheter, data were collected with the source axis at proximal (0.41 mm) and distal (1.19 mm) positions to the film surface in order to investigate dosimetric effects due to the off centering of the source train lumen within the catheter. Absolute doses were determined by calibrating the Gafchromic film in a high-energy electron beam from a radiotherapy accelerator. The absolute dose rates at a distance of 2 mm along the source trains transverse axis were found to be within 13.7% of the values provided by Novoste. Radial dose functions were within 13% compared to 90Sr/Y source train data constructed from Soares' 90Sr/Y single seed data and within 17% and 25% compared to Monte Carlo data by Ye et al., and Wang et al., respectively. Discrepancies of 33% and 19% were observed at short radial distances (< or = 1 mm) between the Novoste Monte Carlo and the 3.5F and 5F catheter measured data, respectively. The source off centering data showed higher dose contribution from the source train at its distal rather than proximal position. Radial dose function comparisons between the Novoste Monte Carlo and the measured data, calculated as a function of radial distance from the catheter's center showed good agreement (< or = 10%).

Download full-text PDF

Source
http://dx.doi.org/10.1118/1.1697695DOI Listing

Publication Analysis

Top Keywords

source train
24
source trains
20
source
13
monte carlo
12
data
10
dosimetric characteristics
8
novoste beta-cath
8
90sr/y source
8
submillimeter distances
8
35f catheter
8

Similar Publications

Advances in artificial intelligence (AI), machine learning, and publicly accessible language model tools such as ChatGPT-3.5 continue to shape the landscape of modern medicine and patient education. ChatGPT's open access (OA), instant, human-sounding interface capable of carrying discussion on myriad topics makes it a potentially useful resource for patients seeking medical advice.

View Article and Find Full Text PDF

Global infectious disease early warning models: An updated review and lessons from the COVID-19 pandemic.

Infect Dis Model

June 2025

Department of Epidemiology and Biostatistics, School of Public Health, Peking University, 38 Xueyuan Road, Beijing, 100191, China.

An early warning model for infectious diseases is a crucial tool for timely monitoring, prevention, and control of disease outbreaks. The integration of diverse multi-source data using big data and artificial intelligence techniques has emerged as a key approach in advancing these early warning models. This paper presents a comprehensive review of widely utilized early warning models for infectious diseases around the globe.

View Article and Find Full Text PDF

This review assesses the antiviral capabilities of antimicrobial peptides (AMPs) against SARS-CoV-2 and other respiratory viruses, focussing on their therapeutic potential. AMPs, derived from natural sources, exhibit promising antiviral properties by disrupting viral membranes, inhibiting viral entry, and modulating host immune responses. Preclinical studies demonstrate that peptides such as defensins, cathelicidins, and lactoferrin can effectively reduce SARS-CoV-2 replication and inhibit viral spread.

View Article and Find Full Text PDF

Background A minority of patients receiving stereotactic body radiation therapy (SBRT) for non-small cell lung cancer (NSCLC) are not good responders. Radiomic features can be used to generate predictive algorithms and biomarkers that can determine treatment outcomes and stratify patients to their therapeutic options. This study investigated and attempted to validate the radiomic and clinical features obtained from early-stage and oligometastatic NSCLC patients who underwent SBRT, to predict local response.

View Article and Find Full Text PDF

Several screening methods are used to detect cervical cancer, with Pap smear test is considered as one of the most reliable screening methods to diagnose cervical cancer. The aim of this study was to investigate the factors associated with awareness of undergoing Pap smear tests among Jordanian women. A cross-sectional study was conducted among 525 Jordanian women attending the outpatient maternity hospital consecutively from February to July 2023.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!