Background: The abnormalities in dilated cardiomyopathy (DCM) are generally considered diffuse and to affect the left ventricle in a global manner. However, regional wall motion abnormalities and metabolic defects may also occur to varying, but unclear degrees. QRS width and metabolic defects on positron emission tomography (PET) correlate with survival. We sought to ascertain the prevalence of regional defects in DCM by multiple imaging modalities and to establish the relationship between QRS width and these defects.
Methods: In consecutive patients with advanced nonischemic DCM, undergoing cardiac transplant evaluation, we reviewed multiple imaging modalities (PET, 2-dimensional echocardiography, and radionuclide ventriculography) to quantify the incidence of regional metabolic and wall motion abnormalities and correlate them with clinical and electrocardiographic parameters.
Results: Of 44 patients studied, PET imaging revealed scar in 91% of patients, with a mean of 25 +/- 18% of the left ventricle involved, predominantly in the distribution of the left anterior descending artery. Regional wall motion abnormalities occurred in 51% of patients who underwent echocardiography and 59% of patients who underwent nuclear scintigraphy (with only 70% concordance). QRS duration on the surface electrocardiogram correlated positively with the degree of scarring (r=.52, P=.0007).
Conclusions: The presence of scar (matched perfusion and metabolic defects) on PET scanning in patients with advanced DCM is not always indicative of coronary disease. Thus coronary angiography is usually required to define the etiology of systolic dysfunction. The extent of scar correlates with QRS duration. This may have implications for the application of cardiac resynchronization therapy.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.cardfail.2003.09.007 | DOI Listing |
Egypt Heart J
January 2025
Department of Cardiology, Hangzhou First People's Hospital, #261 Huansha Road, Hangzhou, 310000, Zhejiang Province, China.
Background: To investigate the optimization of leadless pacemaker placement and to assess its impact on heart synchronization and tricuspid regurgitation.
Results: A clinical trial was conducted involving 53 patients who underwent leadless pacemaker implantation at the Second Affiliated Hospital of Zhejiang University School of Medicine and Hangzhou First People's Hospital between March 2022 and February 2023. Implantation site localization was determined using the 18-segment method under RAO 30° imaging.
Cureus
December 2024
Cardiology, Sri Sathya Sai Institute of Higher Medical Sciences, Bengaluru, IND.
Aim The study aimed to detect subtle left ventricular (LV) systolic dysfunction, reflected by abnormal global longitudinal strain (GLS), in patients with stable coronary artery disease (CAD) undergoing percutaneous coronary intervention (PCI) and to evaluate any improvement in GLS at 24 hours and six months post-PCI. Methods A total of 94 patients with stable CAD scheduled for elective PCI at our hospital were evaluated using conventional 2D echocardiography and GLS prior to the procedure. Follow-up assessments were conducted at 24 hours and six months post-PCI.
View Article and Find Full Text PDFCardiovasc Res
January 2025
Research Institute, Hospital de la Santa Creu i Sant Pau, IIB-Sant Pau, Barcelona, Spain.
Aims: Recurrent acute myocardial infarction (RE-AMI) is a frequent complication after STEMI, and its association with stent thrombosis can be life-threatening. Intravenous atorvastatin (IV-atorva) administration during AMI has been shown to limit infarct size and adverse cardiac remodeling. We determined by cardiac magnetic resonance (CMR) whether the cardioprotection exerted by IV-atorva at the index AMI event translates into a better prognosis upon RE-AMI in dyslipidemic pigs.
View Article and Find Full Text PDFInt J Pharm
January 2025
Amgen Inc., Process Development, Manufacturing Technology Advancement (MTA) Group, Thousand Oaks, CA 91320, USA. Electronic address:
The inspection of liquid-filled vials and syringes using automated visual inspection (AVI) machines is a common practice in pharmaceutical production lines. Liquid drug products are typically agitated using a spin-stop motion to detach particles from the interior surface of the containers, thereby maximizing the probability of their detection. A numerical model for an ISO 8362-1 6R glass vial was developed and validated to qualitatively assess the agitation process for a range of motion profiles, liquid drug product properties, and fill volumes.
View Article and Find Full Text PDFEur Stroke J
January 2025
Neurology and Stroke Unit, ASST Grande Ospedale Metropolitano Niguarda, Milan, Italy.
Background: Severe left ventricular (LV) systolic dysfunction (ejection fraction [EF] < 30%) is a known cardiovascular risk factor and a major cause of cardioembolism. However, less severe forms of LV disease (LVD), such as mild-to-moderate LV dysfunction and LV wall motion abnormalities (LVWMAs), are considered potential minor cardiac sources in Embolic Stroke of Undetermined Source (ESUS), but their role is underexplored. This study aims to evaluate the prevalence of LVD in ESUS and its association with adverse vascular events and mortality.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!