A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Decrease in left ventricular ejection time on digital arterial waveform during simulated hypovolemia in normal humans. | LitMetric

Background: Left ventricular ejection time (LVET) measured in central arteries is modified during hypovolemia. We compared modifications of the pulse wave in a central artery (carotid) and in a peripheral artery (digital) during central hypovolemia induced by lower body negative pressure (LBNP) in conscious volunteers.

Methods: Hypovolemia was simulated with progressive LBNP (baseline, -10, -20, and -30 mm Hg) in nine young healthy volunteers. The carotid arterial pressure waveform was recorded using a Millar tonometric method. The digital pulse wave was measured with a volume-clamp method (Finapres) and the stroke volume with a thoracic impedance method (Biomed).

Results: Mean arterial pressure did not change during LBNP. Compared with baseline values, heart rate increased significantly at the -30 mm Hg level (68 +/- 13 beats/min vs. 59 +/- 11 beats/min), and stroke volume decreased as soon as -10 mm Hg was achieved (113 +/- 41 mL vs. 127 +/- 35 mL). Both carotid and digital LVET decreased significantly at the -10 mm Hg level (337 +/- 26 and 339 +/- 24 ms vs. 360 +/- 35 and 361 +/- 24 ms, respectively).

Conclusion: Peripheral LVET could reflect variation of central LVET during LBNP and be a reliable noninvasive parameter for monitoring hypovolemia.

Download full-text PDF

Source
http://dx.doi.org/10.1097/01.ta.0000063406.34651.e5DOI Listing

Publication Analysis

Top Keywords

left ventricular
8
ventricular ejection
8
ejection time
8
pulse wave
8
arterial pressure
8
stroke volume
8
+/-
8
+/- beats/min
8
decreased -10
8
hypovolemia
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!