A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

An initial investigation of bispectral monitoring as an adjunct to nurse-administered propofol sedation for colonoscopy. | LitMetric

An initial investigation of bispectral monitoring as an adjunct to nurse-administered propofol sedation for colonoscopy.

Am J Gastroenterol

Department of Medicine, Division of Gastroenterology, Indiana University School of Medicine, Indianapolis, Indiana, USA.

Published: June 2004

Background And Aims: Bispectral (BIS) monitoring has been used to evaluate depth of sedation in intensive care and surgical patients. We sought to explore its utility as a monitoring device for nurse-administered propofol sedation (NAPS) during colonoscopy.

Methods: Fifty consecutive patients (ASA I or II) receiving NAPS for outpatient colonoscopy were evaluated. BIS scores, sedation scores, and propofol dosing were correlated. The nurses assessed the usefulness of BIS by questionnaire.

Results: The mean (SD) dose of propofol required to produce a BIS value /= 90 or return to baseline (570 +/- 279.9 s, p < 0.0001). The mean (SD) BIS value in the maintenance phase of sedation was 58.9 (8.53), with a range of 22-88. Nurses administering propofol rated the usefulness of BIS at a mean of 2.85 (maximum usefulness scored as 4) in guiding the dosing of propofol sedation during the maintenance phase of sedation. No patient required mask ventilation or endotracheal intubation.

Conclusions: The BIS index in its current version is not useful in titrating boluses of propofol to an adequate level of sedation, because there is a substantial lag time between decrease of BIS scores to <70 and OAA/S scores indicative of deep sedation. There is also a substantial lag time between recovery of alertness and return of BIS scores to normal. A controlled trial of whether BIS values can assist in avoiding unnecessary propofol dosing during the maintenance phase of sedation appears warranted.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1572-0241.2004.03279.xDOI Listing

Publication Analysis

Top Keywords

nurse-administered propofol
8
propofol sedation
8
initial investigation
4
investigation bispectral
4
bispectral monitoring
4
monitoring adjunct
4
adjunct nurse-administered
4
propofol
4
sedation
4
sedation colonoscopy
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!