AI Article Synopsis

  • This study investigated the effectiveness of the plasma D-dimer test (VIDAS) in diagnosing deep vein thrombosis (DVT) in patients at an emergency department by combining it with a clinical model (Wells score) to improve diagnosis and reduce unnecessary tests.
  • Out of 383 patients, DVT was confirmed in 102 individuals (26.6%), with a high sensitivity (98%) and negative predictive value (98.6%) for the D-dimer test, indicating its reliability in ruling out DVT.
  • The study concludes that incorporating the VIDAS D-dimer test in the diagnostic workflow may enhance patient management for suspected DVT cases, especially for those with initially negative ultrasound results.

Article Abstract

An optimal approach to the diagnosis of deep vein thrombosis (DVT) in lower limbs in the emergency department is still unknown. In this prospective cohort study, we aimed to evaluate the accuracy of the widely available plasma D-dimer test (VIDAS) and establish the usefulness of combining D-dimer testing with a clinical model to reduce the need for serial ultra-sonographies and improve the diagnostic strategy of DVT. We performed a cohort study in 383 consecutive outpatients referred to the emergency department of Hospital La Princesa, with clinical suspicion of DVT. The patients were stratified into three pre-test probability categories using an explicit clinical model (Wells score), and underwent a quantitative automated ELISA D-dimer assay (VIDAS D-Dimer bioMérieux). Patients were managed according to the diagnostic strategy based on clinical probability and compression ultrasonography (CU). Patients for whom DVT was considered a high pre-test probability with negative ultrasonographic findings in the initial CU, returned the following week for repeat ultrasonography. All patients with DVT excluded did not receive anticoagulant therapy, and were followed up for three months to monitor the development of venous thromboembolic complications. DVT was confirmed in 102 patients (26.6%): 95 in the initial test, four in the second test, and three who developed venous thromboembolic complications in the three-month follow-up period. The calculated D-dimer cut-off level was 1 micro g/ml. One hundred patients (98%) with DVT had positive D-dimer. D-dimer had a sensitivity of 98% and a negative predictive value of 98.6%. Among the high-probability patients with positive D-dimer tests and initial negative CU, 9.75% had DVT on repeat CU at one week. The study results suggest that the addition of VIDAS D-dimer to this diagnostic algorithm could improve the management of patients with suspected DVT in daily practice. A diagnostic approach of DVT based on D-dimer (cut-off > or =1 microg/ml) as the first diagnostic tool for the exclusion of DVT, and the clinical probability model as the tool that identifies those patients requiring a second ultrasonography is useful and suitable for daily medical practice.

Download full-text PDF

Source
http://dx.doi.org/10.1160/TH03-02-0080DOI Listing

Publication Analysis

Top Keywords

clinical model
12
dvt
11
patients
10
d-dimer
10
d-dimer test
8
deep vein
8
vein thrombosis
8
emergency department
8
cohort study
8
diagnostic strategy
8

Similar Publications

Objective And Significance: Transforming growth factor-beta (TGF-β) plays a pivotal role in breast development by modulating tissue composition during the developmental phase. The TGFβ type II receptor (TGFβ RII) is implicated in breast cancer and represents a valuable therapeutic target. Due to the off-target side effects of many existing TGFβI/TGFβ RII inhibitors, a more targeted approach to drug discovery is necessary.

View Article and Find Full Text PDF

Background: Solid organ transplantation (SOT) is vital for end-stage organ failure but faces challenges like organ shortage and rejection. Artificial intelligence (AI) offers potential to improve outcomes through better matching, success prediction, and automation. However, the evolution of AI in SOT research remains underexplored.

View Article and Find Full Text PDF

Purpose: Anterior chamber air injection (ACAI) is a surgical technique used to decrease the occurrence of postoperative intraocular lens (IOL) haptic dislocation following phacovitrectomy with gas/air tamponade. The impact of this technique on IOL stability remains uncertain, prompting the design of this study to investigate further.

Methods: This study included 51 eyes of 51 patients who underwent phacovitrectomy with gas/air tamponade.

View Article and Find Full Text PDF

(Group A Streptococcus, GAS) is a human pathogen that causes local and systemic infections of the skin and mucous membranes. However, GAS is also found asymptomatically in the nasopharynx of infants. GAS infections, including pharyngitis and invasive pneumosepsis, pose significant public health concerns.

View Article and Find Full Text PDF

Objective: Evaluate the accuracy and reliability of various generative artificial intelligence (AI) models (ChatGPT-3.5, ChatGPT-4.0, T5, Llama-2, Mistral-Large, and Claude-3 Opus) in predicting Emergency Severity Index (ESI) levels for pediatric emergency department patients and assess the impact of medically oriented fine-tuning.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!