Objectives: The primary objective of this study was to compare two different instruments for assessing digital nerve function; a secondary aim was to determine interobserver agreement among emergency physicians by using static two-point testing of digital nerve function.

Methods: This was a prospective, blinded, observational study of static two-point discrimination involving healthy volunteers aged 18-59 years. The authors compared two instruments (paper clip set or Disk-Criminator) to assess two-point discrimination of the index and long fingers of the dominant hand. For each subject, the initial investigator and initial testing instrument were randomized. Two-point testing was conducted at 4, 5, and 6 mm by using six randomly selected stimuli (1 or 2 points) for each distal phalanx tested. The study was designed to detect a 25% difference in mean two-point distance with a power of 80%.

Results: Seventy-five subjects were entered into the study, of which two were excluded. Interinstrument agreement for a given investigator ranged from 77% to 84% for absolute agreement and 98% to 100% within 2 mm. Weighted kappa values for interobserver differences of 2 mm or less was 0.79 to 1.00. There was no statistically significant difference between instruments.

Conclusions: Using a clinically relevant threshold of 2 mm, the authors found that a properly calibrated set of paper clips performed as well as the Disk-Criminator.

Download full-text PDF

Source

Publication Analysis

Top Keywords

two-point discrimination
12
paper clip
8
digital nerve
8
static two-point
8
two-point testing
8
two-point
6
calibrated paper
4
clip reliable
4
reliable measure
4
measure two-point
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!