A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Factors affecting pain scores during female urethral catheterization. | LitMetric

Factors affecting pain scores during female urethral catheterization.

Acad Emerg Med

Institute for Health Services Research and Policy Studies and Division of Emergency Medicine, Northwestern University, Feinberg School of Medicine, Chicago, IL, USA.

Published: June 2004

Objectives: To compare pain and discomfort ratings of female patients undergoing urethral catheterization randomized to topical application of plain lubricant versus lidocaine gel prior to the procedure.

Methods: This was a prospective, randomized, double-blind study involving female patients requiring urethral catheterization at an urban university-based academic emergency department. A staff nurse blinded to the lubricant type injected 5 mL of sterile surgical lubricant or 2% lidocaine gel into the urinary meatus. After 1 minute, an 8-F (for specimen collection) or a 16-F (for continuous collection) catheter was inserted into the urethra. Each patient rated the pain of the procedure on a validated 0- to 100-mm visual analog scale. The Mann-Whitney U test was used to analyze associations between pain ratings, lubricant type, and catheter size. Logistic regression was used to identify the contribution of lubricant type, catheter size, age category, difficulty of insertion, preprocedural pain, and diagnosis of urinary tract infection to procedural pain rating.

Results: One hundred women were randomized to plain lubricant (n = 50) or lidocaine (n = 50). The overall mean ( +/- SD) pain score was 23.5 +/- 27.2 mm. No significant differences in pain ratings were found based on catheter size or lubricant type. Younger women, aged 18-59 years, experienced higher pain ratings than women aged 60-101 (mean pain difference 14.4 mm; 95% CI = 4.3 to 24.5; p < 0.006). Multiple logistic regression identified preprocedural pain as the only predictor of higher pain rating after catheterization (OR 1.02; 95% CI = 1.002 to 1.039, p = 0.03).

Conclusions: Catheter size and lubricant type did not affect the severity of pain after urethral catheterization in women.

Download full-text PDF

Source

Publication Analysis

Top Keywords

lubricant type
20
urethral catheterization
16
catheter size
16
pain
12
pain ratings
12
female patients
8
lubricant
8
plain lubricant
8
lidocaine gel
8
lubricant lidocaine
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!