Purpose: To evaluate the fate of collateral vessels adjacent to and within the target lesion following subintimal angioplasty (SIA).

Methods: Pre and postprocedural angiograms were reviewed for 29 patients undergoing SIA of the lower extremity arteries over a 3-year period. The number of patent collateral vessels
Results: The mean number of patent collaterals in the proximal segment was 1.9 (range 0-4) preprocedurally and 1.4 (range 0-4) postprocedurally (p<0.002). The mean number of patent collaterals in the distal segment was 1.9 (range 0-4) pre-procedurally and 1.0 (range 0-4) postprocedurally (p<0.0001). Previously absent collaterals within the recanalized segment were observed in 4 (14%) of 29 patients post-SIA. The mean number of collateral vessels within all 3 segments (proximal, treated, and distal) was 3.9 collaterals preprocedurally and 2.9 collaterals postprocedurally.

Conclusions: Some collateral vessels are sacrificed during SIA, but the majority are preserved. In addition, SIA has the potential to open new collaterals within the occluded segment. These collaterals may play an important role should restenosis develop within the target segment.

Download full-text PDF

Source
http://dx.doi.org/10.1583/03-1149.1DOI Listing

Publication Analysis

Top Keywords

collateral vessels
12
fate collateral
8
subintimal angioplasty
8
vessels subintimal
4
angioplasty purpose
4
purpose evaluate
4
evaluate fate
4
vessels adjacent
4
adjacent target
4
target lesion
4

Similar Publications

In Japan, the hinotori™ surgical robot system (Medicaroid Corporation, Kobe, Japan) was approved for gastrointestinal surgeries in October 2022. This report details our initial experience performing liver resection using the hinotori™ system. Ten patients, who were assessed as cases that would benefit from the robot-assisted procedure, underwent liver resections using the hinotori™ system at Fujita Health University, Okazaki Medical Center, between August 2023 and October 2024.

View Article and Find Full Text PDF

The aim of this study was to evaluate patients with hereditary hemorrhagic telangiectasia (HHT) for the potential reperfusion of pulmonary arteriovenous malformations (PAVM) treated by catheter embolization using coils or embolization plugs and to analyze causes of possible reperfusion in order to further improve treatment. This retrospective study analyzed the data of 345 patients who underwent screening for pulmonary arteriovenous malformations in cases of suspected or confirmed HHT (Osler's disease). Of these, 118 patients with PAVM that underwent catheter embolization and had at least one follow-up study were included in our study and evaluated for potential reperfusion.

View Article and Find Full Text PDF

The Circle of Willis (CW) is a critical cerebrovascular structure that supports collateral blood flow to maintain brain perfusion and compensate for eventual occlusions. Increased tortuosity of highrisk vessels within the CW has been implicated as a marker in the progression of cerebrovascular diseases especially in structures like the internal carotid artery (ICA). This is partly due to age-related plaque deposition or arterial stiffening.

View Article and Find Full Text PDF

Background: Pretreatment CT perfusion (CTP) marker relative cerebral blood volume (rCBV) < 42% lesion volume has recently shown to predict poor collateral status and poor 90-day functional outcome. However, there is a paucity of studies assessing its association with hemorrhagic transformation (HT). Here, we aim to assess the relationship between rCBV < 42% lesion volume with HT.

View Article and Find Full Text PDF

Collagen/polyvinyl alcohol scaffolds combined with platelet-rich plasma to enhance anterior cruciate ligament repair.

Biomater Adv

December 2024

College of Biological Science and Engineering, Fuzhou University, No. 2 Xueyuan Road, Fuzhou 350108, China; Fujian Key Laboratory of Medical Instrument and Pharmaceutical Technology, Fuzhou University, No. 2 Xueyuan Road, Fuzhou 350108, China. Electronic address:

In anterior cruciate ligament (ACL) repair methods, the continuous enzymatic erosion of synovial fluid can impede healing and potentially lead to repair failure, as well as exacerbate articular cartilage wear, resulting in joint degeneration. Inspired by the blood clot during medial collateral ligament healing, we developed a composite scaffold comprising collagen (1 %, w/v) and polyvinyl alcohol (5 %, w/v) combined with platelet-rich plasma (PRP). The composite scaffold provides a protective barrier against synovial erosion for the ruptured ACL, while simultaneously facilitating tissue repair, thereby enhancing the efficacy of ACL repair techniques.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!