A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Eight-year results after aortic valve replacement with the Freestyle stentless bioprosthesis. | LitMetric

Eight-year results after aortic valve replacement with the Freestyle stentless bioprosthesis.

J Thorac Cardiovasc Surg

Department of Medicine, Division of Cardiology, University of Michigan, Ann Arbor, 48109, USA.

Published: June 2004

Objectives: We sought to describe the hemodynamic and clinical outcomes for the Freestyle aortic root bioprosthesis (Medtronic, Inc, Minneapolis, Minn) in a large multicenter cohort prospectively followed for 8 years.

Methods: A total of 700 patients (651 [93%] >60 years of age) at 8 centers in North America were followed prospectively after aortic valve replacement with the Freestyle stentless bioprosthesis; the implant technique was subcoronary in 500, total root in 162, and root inclusion in 38. Follow-up was 3395 patient-years (4.9 +/- 2.3 years per patient). Clinical and echocardiographic follow-up was prospectively obtained at yearly intervals.

Results: For the subcoronary, total root, and root inclusion groups, actuarial freedom from valve-related death was 96.8% (SE 3.0%), 92.3% (SE 7.7%), and 90.9% (SE 11.2%), respectively, and freedom from structural deterioration was 98.6% (SE 2.0%), 100.0% (SE 0.0%), and 100.0% (SE 0.0%), respectively. Hemodynamics remained excellent at 6 years. Freedom from moderate or more aortic regurgitation was 86.0% (SE 5.1%), 98.7% (SE 3.9%), and 97.3% (SE 6.6%), respectively. Gradients were slightly lower (P =.0009), and the effective orifice area (P =.02) and freedom from aortic regurgitation were slightly higher (P =.03) with total root than subcoronary implantation.

Conclusions: The Freestyle stentless aortic root bioprosthesis is a versatile option for aortic valve replacement. Measures of clinical outcomes and prosthesis durability remain excellent in multicenter follow-up through 8 years in a population predominantly older than 60 years at the time of the operation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jtcvs.2004.01.023DOI Listing

Publication Analysis

Top Keywords

aortic valve
12
valve replacement
12
freestyle stentless
12
total root
12
replacement freestyle
8
stentless bioprosthesis
8
clinical outcomes
8
aortic root
8
root bioprosthesis
8
root inclusion
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!