Visual inspection-based screening tests, such as visual inspection with 4% acetic acid (VIA) and with Lugol's iodine (VILI), have been proposed as alternatives to cytology in mass screening programs. To date, there is only limited information on the accuracy of these tests in detecting High-grade Squamous Intraepithelial Lesions (HSIL). Eleven cross-sectional studies involving 56,939 women aged 25-65 years were conducted in Burkina Faso, Congo, Guinea, India, Mali and Niger to evaluate the accuracy of VIA and VILI performed by health workers. A common protocol and questionnaire was used. For final diagnosis, all women were investigated with colposcopy and biopsies were taken when necessary. Data from the studies were pooled to calculate sensitivity, specificity and predictive values of the tests for the detection of HSIL. Of the screened women, 16.1% and 16.4% were positive on examination using, respectively, VIA and VILI; 1,063 were diagnosed with HSIL. The pooled sensitivity, specificity, positive and negative predictive values for VIA were 76.8% (95% CI: 74.2-79.4%), 85.5% (95% CI: 85.2-85.8%), 9.4% (95% CI:8.8-10.8%) and 99.5% (95% CI:99.4-99.6%), respectively. The values were 91.7% (95% CI: 89.7-93.4%), 85.4% (95% CI: 85.1-85.7%), 10.9% (95% CI: 10.2-11.6%) and 99.8% (95% CI:99.7-99.9%), respectively for VILI. The range of sensitivity and specificity for VIA was 56.1-93.9% and 74.2-93.8%, respectively, between studies and were 76.0-97.0 % and 73.0-91.3% for VILI. VILI had a significantly higher sensitivity than VIA in detecting HSIL, but specificity was similar. VILI appears to be a more accurate visual test for use in screening and treatment programs in low-resource settings.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/ijc.20190 | DOI Listing |
J Hand Surg Am
January 2025
Hand and Upper Extremity Division of Plastic and Reconstructive Surgery, University of California Davis, Sacramento, CA.
Purpose: Current technologies to define the zone of acute peripheral nerve injury intraoperatively are limited by surgical experience, time, cumbersome electrodiagnostic equipment, and interpreter reliability. In this pilot study, we evaluated a real-time, label-free optical technique for intraoperative nerve injury imaging. We hypothesize that fluorescence lifetime imaging (FLIm) will detect a difference between the time-resolved fluorescence signatures for acute crush injuries versus uninjured segments of peripheral nerves in sheep.
View Article and Find Full Text PDFCrit Rev Anal Chem
January 2025
Department of Chemistry, University of Delhi, New Delhi, India.
Heavy metal pollution is a major environmental and health problem due to the toxicity and persistence of metals such as lead, mercury, cadmium, and arsenic in water, soil, and air. Advances in sensor technology have significantly improved the detection and quantification of heavy metals, providing real-time monitoring and mitigation tools. This review explores recent developments in heavy metal detection, focusing on innovative uses of immobilized chromogenic reagents, nanomaterials, perovskites, and nanozymes.
View Article and Find Full Text PDFSci Rep
January 2025
Research Institute for Applied Microelectronics (IUMA), University of Las Palmas de Gran Canaria (ULPGC), Las Palmas de Gran Canaria, Spain.
Cervical cancer remains a major global health concern, with a specially alarming incidence in younger women. Traditional detection techniques such as the Pap smear and colposcopy often lack sensitivity and specificity and are highly dependent on the experience of the gynaecologist. In response, this study proposes the use of Hyperspectral Imaging, a pioneering technology that combines traditional imaging with spectroscopy to provide detailed spatial and spectral information.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Neurology, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, Republic of Korea.
Distinguishing between Parkinson's disease (PD) and essential tremor (ET) can be challenging sometimes. Although positron emission tomography can confirm PD diagnosis, its application is limited by high cost and exposure to radioactive isotopes. Patients with PD exhibit loss of the dorsal nigral hyperintensity on brain magnetic resonance imaging (MRI).
View Article and Find Full Text PDFBackground: Overexpression of tear matrix metalloproteinases-9 (MMP-9) on the ocular surface tissues has been reported to result in ocular surface damage. MMP-9 levels in tears have been listed as one of many tools for confirming dry eye disease (DED).
Objective: This investigation aimed to compare MMP-9 levels and ocular surface parameters in diabetic patients with and without DED.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!