A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Comparison of clinical performance of troponin T and troponin I in diagnosing acute myocardial infarction]. | LitMetric

In this article we investigate clinical specificity and sensitivity of cardiac troponin T and cardiac troponin I tests in the patients who were admitted to the hospital with suspected acute coronary syndrome. We investigated 87 patients: the clinical investigation was performed, electrocardiogram was recorded and concentrations of cardiac troponin T and troponin I were estimated. According to the recommendations of the manufacturers of troponin T and troponin I tests, threshold diagnostic troponin T concentration for myocardial infarction was considered > or =0.1 ng/ml and troponin I > or =1.0 ng/ml. Troponin T concentration was analyzed in 60 patients; the sensitivity of troponin T test in diagnosing acute myocardial infarction was 85%, and the specificity was 87.2%. Troponin I test was performed in 46 patients; the sensitivity of the test was 76% and the specificity was 76.2%. In case when both troponin T and I tests were performed, the sensitivity of troponin T was 100% and specificity was 78% and of troponin I - respectively 86% and 78%. According to the receiver operator characteristic analysis there was no significant difference between the general accuracy of troponin T and troponin I in distinguishing patients with and without acute myocardial infarction. According to the results of receiver operator characteristic analysis, the biggest clinical sensitivity and specificity were achieved when threshold myocardial infraction diagnostic concentration of troponin T was considered >0.04 ng/ml and of troponin I >0.69 ng/ml.

Download full-text PDF

Source

Publication Analysis

Top Keywords

troponin
20
troponin troponin
16
acute myocardial
12
cardiac troponin
12
troponin tests
12
myocardial infarction
12
ng/ml troponin
12
diagnosing acute
8
troponin concentration
8
patients sensitivity
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!