A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Enantiomeric determination of ephedrine derivatives in unregulated drugs using capillary electrophoresis]. | LitMetric

Capillary electrophoresis (CE) was applied to enantiomeric separation of chiral ephedrine derivatives (d/l-ephedrine, d/l-methylephedrine, d/l-pseudoephedrine, and d/l-norephedrine) in unregulated drug products. Unregulated drugs, referred to as dietary supplements in U.S.A., have been used legally as tonic agents, but illegal substances such as ephedrine were often detected. Baseline separation of all enantiomers of ephedrine derivatives was achieved using an electrophoretic solution containing heptakis (2,6-di-O-methyl)-beta-cyclodextrin (DM-CD) as a chiral selector. The optimal conditions were established to be: capillary column of fused silica (50 microm i.d. x 56 cm); running buffer of 20 mM DM-CD with 50 mM potassium dihydrogenphosphate background electrolyte, pH 2.6; capillary temperature of 20 degrees C; applied voltage of 30 kV; on-column detection at 195 nm; and injection pressure of 50 mbar x 3 s. Under these conditions, all four pairs of enantiomers were sufficiently resolved, and eight peaks were observed with resolution factors of greater than 1.5. The calibration curves of all enantiomers showed good linearity over the concentration range of 2.5-10 microg/ml (r =0.999). The present method was used in a survey of marketed products. The resultant chiral contents were reported and the analytical data were also compared with those from HPLC. This method is useful in the simple and rapid analysis of ephedrine derivatives in marketed products.

Download full-text PDF

Source
http://dx.doi.org/10.1248/yakushi.124.333DOI Listing

Publication Analysis

Top Keywords

ephedrine derivatives
16
unregulated drugs
8
marketed products
8
ephedrine
5
[enantiomeric determination
4
determination ephedrine
4
derivatives
4
derivatives unregulated
4
capillary
4
drugs capillary
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!