[Effect of aortic clamping on hemodynamics at reconstruction of the thoracoabdominal aorta].

Angiol Sosud Khir

Department of Surgical Treatment of Aorta and Great Arteries Diseases, A. N. Bakulev Scientific center of Cardiovascular Surgery, Russian Academy of Medical Sciences, Moscow, Russia.

Published: December 2004

This paper describes an experience with monitoring and computerized follow up of the hemodynamic status in 60 patients at and right after reconstruction of the thoracoabdominal aorta. In addition to the routine control, measurements were made of the pressure in the large vessels and cavities of the heart, duration of each heart contraction and CI. The following parameters were computed automatically: the status of the ventricles for each heart contraction, resistance of the greater end pulmonary circulation, elasticity of the arterial, venous, pulmonary arterial and pulmonary venous reservoirs, also for each cardiac cycle. At the generally accepted monitoring the hemodynamic responses to the surgeon's manipulations on the aorta appear smoothed or are not visualized at all. The control of each heart contraction reveals the responses to application of the clamp and its removal from the aorta, with their hemodynamic significance being not questionable. Aortic clamping and clamp removal from the aorta are associated with the generalized response of the regulatory systems of the body. The slow and thoroughly controlled aortic clamping and graded, controlled blood flow restoration due to clamp removal as well as the use of sodium nitroprusside (trimetafan or isofluran are preferable) allow to avoid an abrupt stroke load of the left ventricle of the heart and, respectively, the generalized response of the regulatory systems of the body.

Download full-text PDF

Source

Publication Analysis

Top Keywords

aortic clamping
12
heart contraction
12
clamp removal
12
reconstruction thoracoabdominal
8
removal aorta
8
generalized response
8
response regulatory
8
regulatory systems
8
systems body
8
heart
5

Similar Publications

A 65-year-old patient was admitted to the Institute with complaints of shortness of breath, palpitation, and limb edema. Comorbidities were type 2 diabetes mellitus, gout, obesity. Echo: left ventricular ejection fraction 22%, left ventricular aneurysm (LVA), floating thrombus 5.

View Article and Find Full Text PDF

Aim: Left atrial (LA) strain is emerging as a valuable metric for evaluating cardiac function, particularly under pathological conditions such as pressure overload. This preclinical study investigates the predictive utility of LA strain on cardiac function in a murine model subjected to pressure overload, mimicking pathologies such as hypertension and aortic stenosis.

Methods: High-resolution ultrasound was performed in a cohort of mice (n = 16) to evaluate left atrial and left ventricular function at baseline and 2 and 4 weeks after transverse aortic constriction (TAC).

View Article and Find Full Text PDF

The optimal management of acute type A aortic dissection (ATAAD) remains a controversial subject. While some surgeons opt for a hemiarch approach to minimize bypass and cross-clamping time, others prefer partial or total arch replacement to prevent the need for additional operations. The advent of hybrid approaches offers a variety of options to the aortic surgeon in treating ATAAD.

View Article and Find Full Text PDF

Adrenomedullin 2/Intermedin Exerts Cardioprotective Effects by Regulating Cardiomyocyte Mitochondrial Function.

Hypertension

January 2025

Department of Cardiovascular Research, Shinshu University School of Medicine, Matsumoto, Nagano, Japan. (Y. Zhao, T. Sakurai, A.K., M.T., Y.I.-S., H.K., Y.M., Y. Zhang, Q.G., P.L., K.H., M.H., J.L., T. Shindo).

Background: Adrenomedullin 2 (AM2) plays critical roles in regulating blood pressure and fluid balance. However, the specific involvement of AM2 in cardiac hypertrophy has not been comprehensively elucidated, warranting further investigation into its molecular mechanisms and therapeutic implications.

Methods: Cardiac hypertrophy was induced in adult mice lacking AM2 (AM2-/-) using transverse aortic constriction surgery.

View Article and Find Full Text PDF

Superior mesenteric artery syndrome in a pediatric patient: A rare case report and literature review.

Int J Surg Case Rep

January 2025

General Surgery Department, Military Hospital of Tunis, Mont Fleury, 1008 Tunis, Tunisia; Faculty of Medicine of Tunis, 15, Djebel Lakhdhar Street, Bab Saadoun, 1007 Tunis, Tunisia.

Introduction And Importance: Superior mesenteric artery (SMA) syndrome, or aorto-mesenteric clamp syndrome, is a rare condition where the third portion of the duodenum is compressed between the aorta and the superior mesenteric artery. This syndrome often affects adolescents and young adults, with predisposing factors including significant weight loss, anatomical variations, and spinal deformities. Early diagnosis and intervention are critical for managing symptoms and preventing complications.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!