Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
HDR surface molds offer an alternative radiotherapy modality to electrons for the treatment of skin lesions. Treatment planning and dosimetry are discussed for two types of surface molds used in our clinic. Standard rectangular applicators are used on a variety of sites where surface curvature is minimal. In these cases an idealized planar geometry is used for treatment planning dose calculations. The calculations yield treatment dose uniformity at the prescription depth in tissue as well as skin dose, as a percentage of the treatment dose, and its dose uniformity. The availability of optimization techniques results in superior dose uniformity at depth but the dose at the skin has to be carefully evaluated. We have studied the dependence of these dosimetric parameters on the size of the surface mold and the type of optimization procedure used in the dosimetry calculations. The second type of surface applicator involves the use of a customized silicone rubber mold attached to a thermoplastic mask of the patient. We have used them to treat lesions of the face where surface curvatures are appreciable and reproducibility of setup is more critical. In these cases a CT data set is used for reconstruction of the catheters, activation of relevant dwell positions and dosimetry, including optimization. Towards establishing effective methods for quality assurance of the optimized HDR surface mold planning calculations, we have compared their dosimetry to both a classical brachytherapy system and to one based on an analytical model of the applicator. The classical system yields an independent verification of the integrated activity used in the planning calculations, whereas the analytical model is used to evaluate depth dose dependence on mold size and optimization.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/153303460400300304 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!