Background: Maze surgery is a final solution for intractable atrial fibrillation (AF), but an adverse effect on postoperative sinus node function has been reported. Whether this also applies to other types of cardiac surgery is unclear.

Methods: We assessed postoperative rhythm by means of repeated exercise tolerance testing, ambulatory electrocardiography, and non-invasive testing of autonomic function between 1 and 12 months after four types of cardiac surgery. Fourteen patients without structural cardiac disease and medically refractory AF underwent the maze III procedure, 11 patients with mitral valve disease and preoperative AF underwent valvar surgery combined with a (simplified) maze III procedure, and 8 patients with mitral valve disease in sinus rhythm (SR) underwent isolated valvar surgery. The control group consisted of eight patients with sinus rhythm who underwent coronary artery bypass surgery (CABG).

Results: One month after surgery, the chronotropic response to exercise was depressed, mean heart rate was high, and heart rate variability (HRV) was low, especially after maze III, combined surgery, and isolated valvar surgery. Twelve months after surgery, moderate improvements were observed. After CABG, considerably fewer abnormalities were observed, and HRV parameters recovered to a large extent. Non-invasive testing of autonomic function indicated disturbed vagal modulation of heart rate in all three groups with atrial incision.

Conclusion: Thus, attenuation of HRV and vagal modulation of sinus node function are not confined to maze surgery but also apply to isolated mitral valve surgery. Atrial incision therefore appears to be crucial and presumably produces autonomic nervous damage followed by partial reinnervation. Nevertheless, cardiac surgery in general seems initially to impair sinus node function with partial recovery in the consecutive 12 months.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijcard.2003.05.002DOI Listing

Publication Analysis

Top Keywords

sinus node
16
node function
16
cardiac surgery
16
surgery
14
maze iii
12
mitral valve
12
valvar surgery
12
heart rate
12
maze surgery
8
types cardiac
8

Similar Publications

Introduction/objective: Atrial fibrillation (AF) could present with slow ventricular-response; bradycardia could facilitate the emergence of AF. The conviction that one "does not succumb" from bradycardia as an escape rhythm will emerge unless one sustains a fatal injury following syncope is in stark difference with ventricular tachyarrhythmia (VA), which may promptly cause cardiac arrest. However, this is not always the case, as a life-threatening situation may emerge during the bradycardic episode, i.

View Article and Find Full Text PDF

The impact of common and rare genetic variants on bradyarrhythmia development.

Nat Genet

January 2025

Telemachus and Irene Demoulas Family Foundation Center for Cardiac Arrhythmias, Massachusetts General Hospital, Boston, MA, USA.

To broaden our understanding of bradyarrhythmias and conduction disease, we performed common variant genome-wide association analyses in up to 1.3 million individuals and rare variant burden testing in 460,000 individuals for sinus node dysfunction (SND), distal conduction disease (DCD) and pacemaker (PM) implantation. We identified 13, 31 and 21 common variant loci for SND, DCD and PM, respectively.

View Article and Find Full Text PDF

Minimizing for Maximum Benefit: An Illustrative Case-Series of Atrial Only Leadless Pacing.

Pacing Clin Electrophysiol

December 2024

Division of Cardiology, Department of Medicine, Weill Cornell Medicine, New York Presbyterian Hospital, New York, USA.

Leadless pacing technology now includesdedicated atrial helix-fixation leadless pacemakers (LPs), expanding theapplication of leadless devices for patients with sinus node dysfunction andatrioventricular block during sinus rhythm. This first reportedcase-series of atrial LPs describes and discusses the potential use-casescenarios of recently approved helix-fixation atrial LPs. The article highlights important concepts regarding their use, including implantationtechniques, programming, battery conservation, and the low rate of progressionof AV block in patients implanted with AAI(R) pacemakers.

View Article and Find Full Text PDF

Reel's syndrome (RS) is an unusual cause of pacemaker lead dislodgement. We present the case of a 59-year-old female patient with Down syndrome (DS) implanted with a dual-chamber endovascular pacemaker due to symptomatic sinus node disfunction, reporting several syncopal episodes in last days and showing abnormal electrical parameters at the 2-months follow-up due to RS. The malfunctioning device was removed and an endocardial leadless pacing system was implanted.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!