Background: Maze surgery is a final solution for intractable atrial fibrillation (AF), but an adverse effect on postoperative sinus node function has been reported. Whether this also applies to other types of cardiac surgery is unclear.
Methods: We assessed postoperative rhythm by means of repeated exercise tolerance testing, ambulatory electrocardiography, and non-invasive testing of autonomic function between 1 and 12 months after four types of cardiac surgery. Fourteen patients without structural cardiac disease and medically refractory AF underwent the maze III procedure, 11 patients with mitral valve disease and preoperative AF underwent valvar surgery combined with a (simplified) maze III procedure, and 8 patients with mitral valve disease in sinus rhythm (SR) underwent isolated valvar surgery. The control group consisted of eight patients with sinus rhythm who underwent coronary artery bypass surgery (CABG).
Results: One month after surgery, the chronotropic response to exercise was depressed, mean heart rate was high, and heart rate variability (HRV) was low, especially after maze III, combined surgery, and isolated valvar surgery. Twelve months after surgery, moderate improvements were observed. After CABG, considerably fewer abnormalities were observed, and HRV parameters recovered to a large extent. Non-invasive testing of autonomic function indicated disturbed vagal modulation of heart rate in all three groups with atrial incision.
Conclusion: Thus, attenuation of HRV and vagal modulation of sinus node function are not confined to maze surgery but also apply to isolated mitral valve surgery. Atrial incision therefore appears to be crucial and presumably produces autonomic nervous damage followed by partial reinnervation. Nevertheless, cardiac surgery in general seems initially to impair sinus node function with partial recovery in the consecutive 12 months.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ijcard.2003.05.002 | DOI Listing |
Curr Vasc Pharmacol
January 2025
Department of Cardiology, Athens University School of Medicine, Athens, Greece.
Introduction/objective: Atrial fibrillation (AF) could present with slow ventricular-response; bradycardia could facilitate the emergence of AF. The conviction that one "does not succumb" from bradycardia as an escape rhythm will emerge unless one sustains a fatal injury following syncope is in stark difference with ventricular tachyarrhythmia (VA), which may promptly cause cardiac arrest. However, this is not always the case, as a life-threatening situation may emerge during the bradycardic episode, i.
View Article and Find Full Text PDFNat Genet
January 2025
Telemachus and Irene Demoulas Family Foundation Center for Cardiac Arrhythmias, Massachusetts General Hospital, Boston, MA, USA.
To broaden our understanding of bradyarrhythmias and conduction disease, we performed common variant genome-wide association analyses in up to 1.3 million individuals and rare variant burden testing in 460,000 individuals for sinus node dysfunction (SND), distal conduction disease (DCD) and pacemaker (PM) implantation. We identified 13, 31 and 21 common variant loci for SND, DCD and PM, respectively.
View Article and Find Full Text PDFKardiol Pol
January 2025
Department of Cardiac Surgery and Transplantology, National Medical Institute, Ministry of Interior and Administration, Center of Postgraduate Medical Education, Warszawa, Poland.
Pacing Clin Electrophysiol
December 2024
Division of Cardiology, Department of Medicine, Weill Cornell Medicine, New York Presbyterian Hospital, New York, USA.
Leadless pacing technology now includesdedicated atrial helix-fixation leadless pacemakers (LPs), expanding theapplication of leadless devices for patients with sinus node dysfunction andatrioventricular block during sinus rhythm. This first reportedcase-series of atrial LPs describes and discusses the potential use-casescenarios of recently approved helix-fixation atrial LPs. The article highlights important concepts regarding their use, including implantationtechniques, programming, battery conservation, and the low rate of progressionof AV block in patients implanted with AAI(R) pacemakers.
View Article and Find Full Text PDFPacing Clin Electrophysiol
December 2024
Electrophysiology and Cardiac Pacing Unit, Pellegrini Hospital, Naples, Italy.
Reel's syndrome (RS) is an unusual cause of pacemaker lead dislodgement. We present the case of a 59-year-old female patient with Down syndrome (DS) implanted with a dual-chamber endovascular pacemaker due to symptomatic sinus node disfunction, reporting several syncopal episodes in last days and showing abnormal electrical parameters at the 2-months follow-up due to RS. The malfunctioning device was removed and an endocardial leadless pacing system was implanted.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!