Endovascular occlusion of wide-necked aneurysms with a new intracranial microstent (Neuroform) and detachable coils.

Neurosurgery

Department of Neurosurgery, Thomas Jefferson University School of Medicine, Jefferson Hospital for Neuroscience, Philadelphia, Pennsylvania 19107, USA.

Published: June 2004

Objective: The long-term durability of the endovascular occlusion of cerebral aneurysms is one of the major factors limiting the more widespread use of this technique. Long-term occlusion of wide-necked aneurysms has improved with new assistive devices that seem to improve aneurysm occlusion while protecting the parent vessel. We report the use of a new intracranial stent--the Neuroform microstent--in the treatment of patients with wide-necked cerebral aneurysms.

Methods: Patients identified as harboring wide-necked intracranial aneurysms were evaluated for stent-assisted coiling. After appropriate anticoagulation was performed, depending on whether the aneurysm was ruptured or unruptured, the Neuroform stent was delivered across the neck of the aneurysm and deployed with a coil pusher. After stent placement, standard coil occlusion of the aneurysm was achieved in the majority of cases.

Results: Fifty-six patients were identified as having wide-necked intracranial aneurysms suitable for stent-assisted coiling. A total of 49 aneurysms in 48 patients were treated with this procedure. In eight cases, stent deployment failed. Forty-one of the aneurysms were initially stented, followed by coil placement. Six aneurysms were stented only, and one aneurysm was initially coiled, followed by stent placement. There were five deaths (8.9%), one of which occurred secondary to a stroke after the procedure (1.8%). Four patients (7%) experienced thromboembolic events, three of which were considered to have been secondary to the procedure (5.3%). In addition, there were two femoral pseudoaneurysms. The overall complication rate was 10.7%. Five patients were available for follow-up angiographic evaluation, and their cases are discussed.

Conclusion: Intracranial stenting may overcome important technical limitations in current endovascular therapy by improving the occlusion of wide-necked aneurysms while protecting the parent vessel.

Download full-text PDF

Source
http://dx.doi.org/10.1227/01.neu.0000124484.87635.cdDOI Listing

Publication Analysis

Top Keywords

occlusion wide-necked
12
wide-necked aneurysms
12
aneurysms
9
endovascular occlusion
8
protecting parent
8
parent vessel
8
patients identified
8
wide-necked intracranial
8
intracranial aneurysms
8
stent-assisted coiling
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!