The purpose of this study was to determine the prognostic significance of a high pretreatment serum CYFRA 21-1 level (a cytokeratin 19 fragment) adjusted for the effects of well-known co-variables in non-small-cell lung cancer (NSCLC). This meta-analysis based on individual updated data gathered comprehensive databases from published or unpublished controlled studies dealing with the prognostic effect of serum CYFRA 21-1 level at presentation in NSCLC of any stage (nine institutions, 2063 patients). Multivariate regression was carried out with the Cox model. The proportional hazard assumption for each of the selected variables retained in the final model was originally checked by log minus log plots baseline hazard ratio. The follow-up ranged from 25 to 78 months. A total of 1616 events were recorded. In the multivariate analysis performed at the 1-year end point, a high pretreatment CYFRA 21-1 level was an unfavourable prognostic determinant in all centres except one (Hazard ratio (95% confidence interval): 1.88 (1.64-2.15), P<10(-4)). Other significant variables were stage of the disease, age and performance status. Within the first 18 months, the procedure disclosed a nearly similar hazard ratio for patients having a high pretreatment serum CYFRA 21-1 level (1.62 (1.42-1.86), P<10(-4)). For patients who did not undergo surgery, the hazard ratio during the first year of follow-up was 1.78 (1.54-2.07), P<10(-4). Finally, in the surgically treated population, at the 2-year end point, a high pretreatment CYFRA 21-1 and a locally advanced stage remained unfavourable prognostic determinants. In conclusion CYFRA 21-1 might be regarded as a putative co-variable in analysing NSCLC outcome inasmuch as a high serum level is a significant determinant of poor prognosis whatever the planned treatment.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2409493PMC
http://dx.doi.org/10.1038/sj.bjc.6601851DOI Listing

Publication Analysis

Top Keywords

cyfra 21-1
16
21-1 level
12
prognostic determinant
8
non-small-cell lung
8
lung cancer
8
2063 patients
8
high pretreatment
8
serum cyfra
8
hazard ratio
8
cyfra
4

Similar Publications

Bladder cancer (BC) is known for its high recurrence rate and requires constant patient monitoring. To confirm the diagnosis, a tissue sample from a cystoscopy is required, which the patient often avoids. Urine has the potential to be utilized as a diagnostic fluid because of its non-invasive nature and various biomarker contents.

View Article and Find Full Text PDF

Repurposing bosentan as an anticancer agent: EGFR/ERK/c-Jun modulation inhibits NSCLC tumor growth.

Fundam Clin Pharmacol

February 2025

Department of Pharmacology and Toxicology, Faculty of Pharmacy, Beni-Suef University, Beni-Suef, 62514, Egypt.

Drug repurposing of well-established drugs to be targeted against lung cancer has been a promising strategy. Bosentan is an endothelin 1 (ET-1) blocker widely used in pulmonary hypertension. The current experiment intends to inspect the anticancer and antiangiogenic mechanism of bosentan targeting epidermal growth factor receptor (EGFR) /extra-cellular Signal Regulated Kinase (ERK) /c-Jun/vascular endothelial growth factor (VEGF) carcinogenic pathway.

View Article and Find Full Text PDF

This study investigates the prognostic value of serum biomarkers PD-L1 and IGFBP-2 in patients with esophageal carcinoma. It finds a significant positive correlation between these biomarkers and established tumor markers CEA and CYFRA21-1. The 3-year survival rate for the patient cohort was 45.

View Article and Find Full Text PDF

Non-small cell lung cancer (NSCLC) is the predominant form of lung cancer and poses a significant public health challenge. Early detection is crucial for improving patient outcomes, with serum biomarkers such as carcinoembryonic antigen (CEA), squamous cell carcinoma antigen (SCCAg), and cytokeratin fragment 19 (CYFRA 21-1) playing a critical role in early screening and pathological classification of NSCLC. However, due to being mainly based on corresponding antibody binding reactions, existing detection technologies for these serum biomarkers have shortcomings such as complex operations, high false positive rates, and high costs.

View Article and Find Full Text PDF

A novel approach to developing lateral flow assays (LFAs) for the detection of CYFRA 21-1 (cytokeratin 19 fragment, a molecular biomarker for epithelial-origin cancers) is proposed. Magnetic bioconjugates (MBCs) were employed in combination with advanced optical and magnetic tools to optimize assay conditions. The approach integrates such techniques as label-free spectral-phase interferometry, colorimetric detection, and ultrasensitive magnetometry using the magnetic particle quantification (MPQ) technique.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!