Multichannel place pitch sensitivity in cochlear implant recipients.

J Assoc Res Otolaryngol

Laboratory for Experimental ORL, Katholieke Universiteit Leuven, Kapucijnenvoer 33, 3000, Leuven, Belgium.

Published: September 2004

Cochlear implant recipients perceive a rise in pitch when the site of stimulation is moved from the apex toward the base. The place pitch sensitivity is typically measured using the stimulation of single channels. However, all current cochlear implant devices stimulate multiple channels simultaneously or with pulses temporally interleaved. The primary goal of the present study is to test whether the sensitivity of a cochlear implant recipient to changes in perceived pitch associated with changes of place of excitation improves or deteriorates when the number of active channels is increased, compared with stimulation with only one active channel. Place pitch sensitivity was recorded in four Nucleus CI24 subjects as a function of number of active channels (from 1 to 8). Just noticeable differences were estimated from a constant stimuli 2AFC pitch-ranking experiment with roving loudness. Reference and comparison stimuli contained the same number of active channels but were shifted one or two electrodes toward the base or toward the apex. The place pitch sensitivity was measured using monopolar stimulation at two locations along the electrode array. To minimize cues related to loudness, the multichannel stimuli were loudness balanced relative to the single-channel stimuli presented at C-level. The number of active channels did not affect place pitch sensitivity. This is consistent with a model that compares the edges of the excitation pattern irrespective of the overlap between excitation patterns. There was a significant difference in sensitivity to place pitch among subjects. The average just noticeable differences of place pitch, extrapolated from a fitting procedure, for the subjects ranged from 0.25 mm to 0.46 mm.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2504550PMC
http://dx.doi.org/10.1007/s10162-004-4049-yDOI Listing

Publication Analysis

Top Keywords

place pitch
28
pitch sensitivity
20
cochlear implant
16
number active
16
active channels
16
pitch
9
sensitivity cochlear
8
implant recipients
8
noticeable differences
8
sensitivity
7

Similar Publications

Objective: What we hear may influence postural control, particularly in people with vestibular hypofunction. Would hearing a moving subway destabilize people similarly to seeing the train move? We investigated how people with unilateral vestibular hypofunction and healthy controls incorporated broadband and real-recorded sounds with visual load for balance in an immersive contextual scene.

Design: Participants stood on foam placed on a force-platform, wore the HTC Vive headset, and observed an immersive subway environment.

View Article and Find Full Text PDF

and Aims We conducted this research motivated by the incomplete knowledge of the changes made by resonance and harmonic filtering processes made by articulatory gestures in the supralar-yngeal level of the vocal tract. Aim of research The goal of the study is to evaluate the adaptive changes taking place at the oropharyngeal isthmus during sustained phonation. Methods We focused on exploring the dynamics of the oropharyngeal pavilion in voice professionals using Cone-Beam Computed Tomogra-phy (CBCT).

View Article and Find Full Text PDF

The PULSE workload monitor (PULSE) is a commercially available, wearable device that assesses upper extremity kinematics and kinetics during overhand pitching with three metrics to improve pitching performance. The purpose of this study was to determine the inter-tester and intra-tester reliability of the PULSE metrics when applied by a lay consumer versus trained researcher. A total of 14 healthy, adult male (age: 44.

View Article and Find Full Text PDF

Injuries are commonplace in the overhead athlete, with many occurring to the shoulder and elbow. The increasing prevalence of injuries to the shoulder and elbow has been discussed at length in recent years, with increased research focus being placed on arm care for rehabilitation and prevention strategies. Even though the pitching motion is well-established as a whole-body kinetic chain movement, most attention in rehabilitation and prevention efforts is often placed on the upper extremity.

View Article and Find Full Text PDF

Learning to hear again with alternating cochlear frequency allocations.

Sci Rep

January 2025

Department of ENT/Audiology & School for Mental Health and NeuroScience (MHENS), Maastricht University Medical Centre, Maastricht, The Netherlands.

Traditionally, the place-pitch 'tonotopically' organized auditory neural pathway was considered to be hard-wired. Cochlear implants restore hearing by arbitrarily mapping frequency-amplitude information. This study shows that recipients, after a long period of sound deprivation, preserve a level of auditory plasticity, enabling them to swiftly and concurrently learn speech understanding with two alternating, distinct frequency maps.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!