Rational And Objectives: The effects of electrolytes, viscosity, and chemotoxicity of a plasma-isotonic iodine contrast medium iodixanol were compared with regard to its propensity to cause ventricular fibrillation (VF).

Materials And Methods: The left coronary artery of pigs was perfused with five isotonic solutions: iodixanol 320 mg I/mL with 19 mmol/L NaCl + 0.3 mmol/L CaCl2, Iod 320+Mann (iodixanol 320 mg I/mL + 50 mmol/L mannitol), Mann+Na/Ca (240 mmol/L mannitol with 19 mmol/L NaCl + 0.3 mmol/L CaCl2), Mann (275 mmol/L mannitol) and Ringer. The first two solutions have at 37 degrees C a viscosity of approximately 13 mPa x s while the others have a viscosity < 1 mPa x s. In eight pigs, each test solution was injected twice into the left coronary artery in random order for 10 seconds (injection volume, 20 mL). In 15 pigs, each of the solutions was injected in random order for 11-40 seconds through the end-hole of a wedged 5F balloon catheter in left coronary artery. Injection rate was 0.5 mL/sec until VF occurred. If VF occurred, injection was stopped and the heart was defibrillated. If VF did not occur, the perfusion period was 40 seconds.

Results: The 10-second perfusions caused no VF. The 40-second perfusions with iodixanol 320 mg I/mL with 19 mmol/L NaCl + 0.3 mmol/L CaCl2 or Ringer caused no VF (0%). Iod 320+Mann caused nine VF (60%) after 35 +/- 4 seconds (SEM). Mann+Na/Ca caused 14 VF (93%) after 30 +/- 2 seconds. Mann caused 15 VF (100%) after 24 +/- 2 seconds. Iodixanol 320 mg I/mL with 19 mmol/L NaCl + 0.3 mmol/L CaCl2 and Ringer caused fewer VF than all other solutions (P < .05-.001). Iod 320+Mann caused fewer VF than Mann (P < .05). Iod 320+Mann caused VF later than Mann+Na/Ca or Mann (P < .02 and P < .01). Mann+Na/Ca caused VF later than Mann (P < .05).

Conclusion: The results fit with a concept that VF starts when the electrolyte composition of the interstitial fluid in the myocardium is sufficiently nonphysiologic. The more physiologic the electrolyte composition of the perfusion fluid, and the higher its viscosity, the slower the composition of the interstitial fluid will be changed, and VF will occur later (or not at all).

Download full-text PDF

Source
http://dx.doi.org/10.1016/S1076-6332(03)00815-8DOI Listing

Publication Analysis

Top Keywords

left coronary
16
coronary artery
16
iodixanol 320
16
320 i/ml
16
i/ml mmol/l
16
mmol/l nacl
16
nacl mmol/l
16
mmol/l cacl2
16
iod 320+mann
16
mmol/l mannitol
12

Similar Publications

Effect of heart rate on B-type natriuretic peptide in sinus rhythm.

Sci Rep

December 2024

Division of Cardiology, Department of Internal Medicine, The Jikei University School of Medicine, 3-25-8 Nishi-shimbashi, Minato-ku, Tokyo, 105-8461, Japan.

B-type natriuretic peptide (BNP) levels accurately reflect the degree of cardiac overload in heart failure. Considering cardiac morphology and intracardiac pressure, including the left ventricular end-systolic volume index (LVESVI) and left ventricular end-diastolic volume index (LVEDVI), is essential for cardiac overload assessment. These indexes influence plasma BNP levels, and high heart rate is likely associated with cardiac morphology.

View Article and Find Full Text PDF

We present a case of a 72-year-old female patient with dyspnea and lipothymia. Echocardiography demonstrates an intracavitary cystic mass that fills almost all left atria causing supravalvular obstruction. The magnetic resonance image revealed a 53 × 47 × 48 mm heterogeneous mass with regular edges, tissue characterization suggested myxoma.

View Article and Find Full Text PDF

Background: The new Amplatzer Steerable Delivery Sheath is a delivery system designed to improve ease-of-use and procedural results of left atrial appendage closure (LAAC). We aimed to compare procedural results after switching our LAAC program at a tertiary care center with the Amulet device to the Steerable Delivery Sheath, with a control group of LAAC employing the standard sheath.

Methods: The first n = 32 consecutively treated patients at our site using the Amulet device with the Steerable Delivery Sheath were included in this retrospective analysis.

View Article and Find Full Text PDF

Background: Despite advancements in valve implantation devices, vascular access complications (VAC) remain a significant cause of morbidity and mortality for those undergoing transcatheter aortic valve replacement (TAVR). We describe pre-operative imaging analysis of the aortoiliac and femoral arterial beds using the TransAtlantic intersociety consensus (TASC) score, ilio-femoral tortuosity, and procedural characteristics to identify anatomic risk factors predictive of VAC in TAVR.

Methods: Consecutive patients undergoing TAVR from 2012 to 2022 at a single North Dakota hospital were retrospectively reviewed.

View Article and Find Full Text PDF

A rare cardiac presentation of a lymphoma: case report.

Eur Heart J Case Rep

January 2025

Department of Cardiology, Klinik Floridsdorf, Brünnerstraße 68, Vienna 1210, Austria.

Background: Cardiac lymphoma is a rare disease that can present in various ways. Additionally, atypical clinical presentation makes the diagnosis even more challenging. The most common type of cardiac lymphoma is diffuse large B-cell lymphoma.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!