Non-absorbing alkyl ether sulfates (AES) can be separated using anthraquinone-2-carboxylic acid (AQCA) as a probe; however, absorbing alkyl benzene sulfonates (ABS), if present, interfere indirect detection of most AES oligomers. Overcoming of this interference, as well as the simultaneous characterisation and evaluation of AES, fatty acids and ABS, was accomplished by using a diode-array detector and the procedures here discussed. First, it was shown that ABS can be made undetectable by using a 9 nm wide and 227 nm centred charge-absorptivity null-balance detection window (NBDW), where its contribution to the absorbance cancels the dilution effects that its presence induces on the signal of the background chromophore (BGC). Two other procedures, not requiring any prior knowledge on the nature of the absorbing interference, were also addressed. In the first one, the NBDW procedure was emulated by software, by treating the time-wavelength data matrix stored during the experimental run, and in the second one, both the ABS and BGC spectra, and the concentration profiles of ABS and the non-absorbing solutes, were recovered by orthogonal projection approach (OPA) and alternating least squares (ALS). The OPA-ALS processing provided the deconvolved signals and the wavelengths required to implement the experimental and software-emulated NBDW procedures. A composite ABS spectrum and a mixed concentration profile of the non-absorbing solutes, that involves mutual ABS-BGC dilution effects are enclosed in the OPA-ALS straightforward solutions. The pure spectra and concentration profiles were finally retrieved by crossed orthogonalisation. For the NBDW procedures, the limits of detection (S/N = 3) for AES oligomers overlapped by 1500 microg ml(-1) ABS were of ca. 10 microM AES. Using decyl sulfate as internal standard, the relative standard deviation for AES in an ABS containing industrial sample was 4.5%. The procedures here described are useful to remove the interference produced by any absorbing solute when overlapped with indirectly detected solutes in both capillary electrophoresis (CE) and HPLC.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.chroma.2004.03.018 | DOI Listing |
J Chromatogr A
May 2004
Departament de Química Analítica, Facultad de Química, Universitat de València, Dr. Moliner 50, Burjassot, Valencia 46100, Spain.
Non-absorbing alkyl ether sulfates (AES) can be separated using anthraquinone-2-carboxylic acid (AQCA) as a probe; however, absorbing alkyl benzene sulfonates (ABS), if present, interfere indirect detection of most AES oligomers. Overcoming of this interference, as well as the simultaneous characterisation and evaluation of AES, fatty acids and ABS, was accomplished by using a diode-array detector and the procedures here discussed. First, it was shown that ABS can be made undetectable by using a 9 nm wide and 227 nm centred charge-absorptivity null-balance detection window (NBDW), where its contribution to the absorbance cancels the dilution effects that its presence induces on the signal of the background chromophore (BGC).
View Article and Find Full Text PDFAppl Opt
March 1966
Department of Chemical Engineering, University of Idaho, Moscow, Idaho.
Automatic control theory was applied to the null-balance processing of spectral data generated by a vidicon television camera. The spectrum, after passing through reference and sample cells, was focused on the vidicon faceplate. The camera detects a single wavelength with each horizontal scan.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!