Objective: This paper reports the results of a prospective multicenter clinical study on immediately fully occlusally loaded full-arch screw-retained prostheses with distal extensions (hybrid prostheses) supported by Osseotite implants inserted in edentulous lower jaws.
Method And Material: Sixty-two patients were enrolled in four clinical centers. Three hundred and twenty-five Osseotite implants were inserted and occlusally loaded according to an immediate loading protocol. The temporary prosthesis was delivered 4 h from surgery. The final prosthesis was delivered after 6 months. Marginal bone loss was monitored from periapical radiographs using a computerized technique.
Results: Two implants failed to integrate within 2 months of occlusal loading. A cumulative implant success rate of 99.4% was achieved for a period of 12-60 months postplacement (mean 28.6+/-14.1 (SD) months). Crestal bone loss around the immediately loaded implants was similar to that reported for standard delayed loading protocols.
Conclusion: The results of this study suggest that the rehabilitation of the edentulous mandible by an immediate occlusally loaded hybrid prosthesis supported by five to six Osseotite implants represents a viable alternative treatment to classic delayed loading protocols.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1600-0501.2004.01013.x | DOI Listing |
J Clin Med
August 2024
Department of Oral and Maxillofacial Surgery, University Medical Center Groningen and University of Groningen, 9700 RB Groningen, The Netherlands.
The long-term effects of implant properties, such as implant length, platform switch, and crown splinting, on peri-implant health require more investigation. Therefore, the aim was to assess the long-term peri-implant health and patient satisfaction in a patient cohort, obtained from two prospective randomized controlled trials, who received 8.5 mm long dental implants, with either splinted or solitary suprastructures and with or without a platform switch, over a period of 15 years.
View Article and Find Full Text PDFPurpose: To retrospectively evaluate the long-term clinical, technical, biological, and esthetic outcomes of implant supported single zirconia crowns (ISCs) intraorally cemented to Ti-base hybrid-abutments up to 16 years after placement.
Materials And Methods: A total of 63 ISCs (Xive S, Camlog Screw Line, Replace Select TC NP, Branemark MK II, and 3i Osseotite) were evaluated in 36 patients at two different centers. Original Ti-bases were selected and zirconia meso structures and zirconia crowns were designed using CAD/CAM software and then milled from partially stabilized zirconia blocks.
Clin Oral Implants Res
June 2024
J. L. Calvo-Guirado, G.
View Article and Find Full Text PDFJ Pharm Bioallied Sci
July 2023
Department of Dental Hygienec, College of Applied Health Sciences in Ar Rass, Qassim University, Saudi Arabia.
Objectives: We compared the loads at which the implant holders from Astra Tech (AST) (AstraOsseoSpeed) and Osseotite Certain failed under static compression after experiencing fatigue, as well as the gap that resulted from dynamic loading between the implant-holder complexes.
Materials And Method: The ISO 14801 recommendation served as the foundation for the test protocol. Each brand's five implant-implant holder assemblies underwent dynamic loading.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!