Occurrence and volatility of several trace elements in pulverized coal boiler.

J Environ Sci (China)

Education Ministry Key Laboratory on Clean Coal Power Generation and Combustion Technology, Southeast University, Nanjing 210096, China.

Published: August 2004

The contents of eight trace elements(Mn, Cr, Pb, As, Se, Zn, Cd, Hg) in raw coal, bottom ash and fly ash were measured in a 220 t/h pulverized coal boiler. Factors affecting distribution of trace elements were investigated, including fly ash diameter, furnace temperature, oxygen content and trace elements' characters. One coefficient of Meij was also improved to more directly show element enrichment in combustion products. These elements may be classified into three groups according to their distribution: Group 1: Hg, which is very volatile. Group 2: Pb, Zn, Cd, which are partially volatile. Group 3: Mn, which is hardly volatile. Se may be located between groups 1 and 2. Cr has properties of both group 1 and 3. In addition, the smaller diameter of fly ash, the more relative enrichment of trace elements (except Mn). The fly ash showed different adsorption mechanisms of trace elements and the volatilization of trace elements rises with furnace temperature. Relative enrichments of trace elements(except Mn and Cr) in fly ash are larger than that in bottom ash. Low oxygen content can not always improve the volatilization of trace elements. Pb is easier to form chloride than Cd during coal combustion. Trace elements should be classified in accordance with factors.

Download full-text PDF

Source

Publication Analysis

Top Keywords

trace elements
28
fly ash
20
trace
10
elements
8
pulverized coal
8
coal boiler
8
bottom ash
8
furnace temperature
8
oxygen content
8
elements classified
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!