The purpose of this study was to evaluate the scope of sub-millimeter collimation reconstruction parameters using 16-row computer tomography and ECG triggering on image quality in virtual bronchoscopy. Thirty-two patients (5 women, 27 men, mean age 66.6+/-1.4) who had been admitted for coronary artery bypass graft surgery underwent CT examination of the thorax (Sensation 16, Siemens, Inc., Forchheim, Germany). All patients were examined with 16x0.75-mm collimation. Image reconstruction was performed for two groups. In group A ( n=32), slice thickness of 1.5 mm and an overlap of 0.75 mm were used. In group B ( n=32), slice thickness of 0.75 mm and an overlap of 0.4 mm were applied. Retrospective ECG triggering was performed in all patients. The maximum order of recognizable bronchi was determined in each data set. In addition to assessing the maximum order of bronchial bifurcation, bronchial diameter was determined in truly perpendicular sections in each patient. For every segment proximal to a bifurcation, image quality was subjectively graded as poor (grade 1), moderate (grade 2) or good (grade 3). The observers were asked to identify the minimum cardiac movement ECG-triggered image sets assuming that they would be of better quality than the maximum cardiac movement ECG-triggered image sets. The Mann-Whitney U-test and the Fisher's Exact Test were used for statistical evaluation. In group A, a mean of 4.8+/-0.2 bifurcations was ascertained vs. 6.5+/-0.3 bifurcations in group B [ P<0.0003]. For bronchial diameters in group A, a mean of 7.5+/-0.4 mm was determined vs. 4.6+/-0.4 mm in group B [ P<0.0001]. In group B, two independent radiologists observed a significant shift to better image quality in all segments evaluated [ P<0.006 to P<0.000001]. Motion artifacts were judged as being significantly reduced by minimum cardiac movement ECG-triggering in group B [observer 1: P=0.0007 (20/32); observer 2: P=0.008 (18/32)], but not in group A [observer 1: P=0.286 (13/32); observer 2: P=0.123 (16/32)]. Sub-millimeter collimation and minimum cardiac movement ECG-triggered data acquisition allow deeper penetration into the tracheo-bronchial system allowing visualization of the bronchial surface down to diameters below 5 mm in certain cases up to the eighth bifurcation. Along with an enhanced visualization as such, better image quality is acquired in all segments evaluated. Trade off between better image quality, of doubtful diagnostic consequence, and much higher irradiation dose must be made.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00330-004-2325-1DOI Listing

Publication Analysis

Top Keywords

sub-millimeter collimation
8
ecg triggering
8
image quality
8
group n=32
8
n=32 slice
8
slice thickness
8
maximum order
8
cardiac movement
8
movement ecg-triggered
8
ecg-triggered image
8

Similar Publications

Challenges for the Implementation of Primary Standard Dosimetry in Proton Minibeam Radiation Therapy.

Cancers (Basel)

November 2024

Radiotherapy and Radiation Dosimetry, National Physical Laboratory, Teddington TW11 0LW, UK.

Article Synopsis
  • Spatial fractionation of proton fields in cancer treatment improves sparing of healthy tissue while ensuring tumor control.
  • This study demonstrated the use of the National Physical Laboratory's Primary Standard Proton Calorimeter to measure absorbed dose in a proton beam with a specific configuration.
  • Results indicated that uncertainty in absorbed dose measurements was mainly due to positioning accuracy, suggesting that reference dosimetry should focus on measuring Dose-Area Product or using SOBP for more reliable outcomes in spatially fractionated fields.
View Article and Find Full Text PDF

Grating couplers are widely used in integrated optics to generate free-space beams and facilitate localized interactions with systems such as atom or ion traps. However, etched devices often exhibit small-scale inconsistencies; exacerbated by the high index contrast of the devices, this can lead to phase errors, limiting devices to a sub-millimeter scale. Here we present the first demonstration, to our knowledge, of tilted, out-of-plane blazed gratings in planar silica fabricated by UV inscription using a 213 nm laser.

View Article and Find Full Text PDF

Purpose: To develop an angular correction methodology and characterize a high-resolution complementary metal-oxide-semiconductor (CMOS) array for patient specific quality assurance on a robotic arm linear accelerator.

Methods: Beam path files from the treatment planning software (TPS) were used to calculate the angle of radiation beam with respect to the detector plane. Beams from multiple discrete angles were delivered to the CMOS detector array and an angular dependency look up table (LUT) was created.

View Article and Find Full Text PDF

Purpose: End-to-end testing (E2E) is a necessary process for assessing the readiness of the stereotactic radiosurgery (SRS) program and annual QA of an SRS system according to the AAPM MPPG 9a. This study investigates the differences between using a new SRS MapCHECK (SRSMC) system and an anthropomorphic phantom film-based system in a large network with different SRS delivery techniques.

Methods And Materials: Three SRS capable Linacs (Varian Medical Systems, Palo Alto, CA) at three different regional sites were chosen to represent a hospital network, a Trilogy with an M120 multi-leaf collimator (MLC), a TrueBeam with an M120 MLC, and a TrueBeam Stx with an HD120 MLC.

View Article and Find Full Text PDF

Although wafer-scale single-grain thin films of 2D metal chalcogenides (MCs) have been extensively sought after during the last decade, the grain size of the MC thin films is still limited in the sub-millimeter scale. A general strategy of synthesizing wafer-scale single-grain MC thin films by using commercial wafers (Si, Ge, GaAs) both as metal source and epitaxial collimator is presented. A new mechanism of single-grain thin-film formation, surface diffusion, and epitaxial self-planarization is proposed, where chalcogen elements migrate preferentially along substrate surface and the epitaxial crystal domains flow to form an atomically smooth thin film.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!