Continuous measurement of cardiac output (CCO) is useful in assessing the cardiovascular status of patients during cardiac surgery and in intensive care. Recently, a CCO system (truCCOMS, Aortech, UK), capable of detecting rapid changes in cardiac output (CO) was introduced. The method is based on the energy required to maintain an integral heat-transfer device at constant temperature above the ambient value. The aim of this study was to assess the performance of this CCO system in vitro under in steady as well as pulsatile flow conditions representative of those in the pulmonary artery. In order to determine the sensitivity of the system to changes in vessel cross-sectional area and therefore local flow velocity, the catheter was deployed in a linear-tapered tube. Steady and pulsatile flows were generated, and the electrical power at various locations along the tapered tube was recorded. The results show significant differences in the performance under the two different flow conditions. In steady flow, the CO was highly dependent on the local velocity whereas in pulsatile flow, CO varied much less with local velocity. The sensitivity expressed as a percentage increase in CO per 100% increase in velocity at a CO of 5 l min(-1) was 87% in steady flow and 24% in pulsatile flow. Experiments carried out with three fluids with different viscosity show that the errors in determining CO in the tapered tube were also dependent on the Reynolds number and flow regime. The mean errors ranged from about 50% at 2 l min(-1) to less than 10% at 8 l min(-1). The correlation between the predicted and actual CO was generally good. In conclusion, the pulmonary artery catheter is not recommended in situations where blood flow is expected to be steady or of low pulsatility. It may, however, be suitable under normal pulsatile flow conditions in the pulmonary artery.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1088/0967-3334/25/2/005 | DOI Listing |
Multimed Man Cardiothorac Surg
January 2025
Congenital Heart Center, Division of Cardiovascular Surgery, Department of Surgery, University of Florida, Gainesville, FL, USA.
The Berlin Heart EXCOR is a pulsatile paracorporeal ventricular assist device (VAD) for neonates, infants, children and adults with congenital or acquired severe ventricular dysfunction. Berlin Heart EXCOR VADs are routinely used as either a bridge to a cardiac transplantation, or occasionally as a bridge to ventricular recovery. Our programmatic philosophy is to bridge neonates and infants with functionally univentricular ductal-dependent systemic circulation or functionally univentricular ductal-dependent pulmonary circulation who are at high risk for staged palliation because of important cardiac risk factors with a single-ventricle VAD (sVAD) as a bridge to a cardiac transplant.
View Article and Find Full Text PDFComput Biol Med
January 2025
Department of Mechanical Engineering, Isfahan University of Technology, Isfahan, Iran. Electronic address:
Atherogenesis is prone in medium and large-sized vessels, such as the aorta and coronary arteries, where hemodynamic stress is critical. Low and oscillatory wall shear stress contributes significantly to endothelial dysfunction and inflammation. Murray's law minimizes energy expenditure in vascular networks and applies to small arteries.
View Article and Find Full Text PDFJ Appl Physiol (1985)
January 2025
Medical Physics Graduate Program, Duke University, Durham, North Carolina, United States.
Hyperpolarized Xe MRI/MRS enables quantitative mapping of function in lung airspaces, membrane tissue, and red blood cells (RBCs) within the pulmonary capillaries. The RBC signal also exhibits cardiogenic oscillations that are reduced in pre-capillary pulmonary hypertension (PH). This effect is obscured in patients with concomitant defects in transfer from airspaces to RBCs, which increase RBC oscillation amplitudes.
View Article and Find Full Text PDFCardiovasc Eng Technol
January 2025
Institute for Medical Engineering and Science, Massachusetts Institute of Technology, MA, Cambridge, USA.
Purpose: Atrial fibrillation (AF) is the most common chronic cardiac arrhythmia that increases the risk of stroke, primarily due to thrombus formation in the left atrial appendage (LAA). Left atrial appendage occlusion (LAAO) devices offer an alternative to oral anticoagulation for stroke prevention. However, the complex and variable anatomy of the LAA presents significant challenges to device design and deployment.
View Article and Find Full Text PDFRev Cardiovasc Med
January 2025
Center for Preclinical Surgical & Interventional Research, The Texas Heart Institute, Houston, TX 77030, USA.
The evolution of left ventricular assist devices (LVADs) from large, pulsatile systems to compact, continuous-flow pumps has significantly improved implantation outcomes and patient mobility. Minimally invasive surgical techniques have emerged that offer reduced morbidity and enhanced recovery for LVAD recipients. Innovations in wireless power transfer technologies aim to mitigate driveline-related complications, enhancing patient safety and quality of life.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!