A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Investigation of the activation of a human serum complement protein, C3, by orthopedic prosthetic particulates. | LitMetric

Investigation of the activation of a human serum complement protein, C3, by orthopedic prosthetic particulates.

Biomaterials

Department of Orthopaedic Surgery MRB 106, Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, Boston, MA 02115, USA.

Published: October 2004

Myriad molecular, cellular, and physiological processes underlie the inflammatory and osteolytic processes induced by particles of biomaterials resulting from the wear of implants such as total joint replacement prostheses. The objective this study was to investigate the role that the complement system may be playing in these phenomena. The aim was to evaluate the degree to which particles of selected orthopaedic materials--high density and ultrahigh molecular weight polyethylene, polymethylmethacrylate, and commercially pure titanium--cause the elevation of a key complement molecule, C3a, in an in vitro assay that directly measured the concentration of C3a. The results demonstrated that HDPE particles, at high concentration, are capable of causing the elevation of C3a in the in vitro assay. This finding is discussed in the context of other work and the mechanics of the complement system as it may affect the osteolytic process.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.biomaterials.2003.11.057DOI Listing

Publication Analysis

Top Keywords

complement system
8
c3a vitro
8
vitro assay
8
investigation activation
4
activation human
4
human serum
4
complement
4
serum complement
4
complement protein
4
protein orthopedic
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!