[Evaluation of the AOAC 985.29 enzimic gravimetric method for determination of dietary fiber in oat and corn grains].

Arch Latinoam Nutr

Centro de Ciências Rurais da Universidade Federal de Santa Maria, Universidade Federal do Rio Grande do Sul, Universidade do Rio Grande, Brasil.

Published: December 2003

The precision attributes and use of the enzymatic-gravimetric method of Prosky et al. (1992) (AOAC 985.29) were evaluated using corn (BR 5202 Pampa) and oat (UFRGS 15) samples. The effect of laboratory batches carried out in different days were evaluated in six laboratory batches, using for each material one duplicate for total fiber (FT) determination, one duplicate for insoluble fiber (FI) determination and blank ones for FT and for FI (both in duplicate). In order to characterize repetitive aspects, five other FT and FI determinations added to each sample were evaluated, summing up 11 data. The low coefficients of variation in the first six batches were considered acceptable as an expression of expected total intralaboratory variation. The repetitive of the method was considered good for FT determinations (CVs < 10%). However, in the FI determination a high frequency of negative values of ash and blanks was found, impairing the repetitive aspects evaluation. The magnitude of the total gravimetric corrections varies with the kind of the sample and is especially influenced by the protein content.

Download full-text PDF

Source

Publication Analysis

Top Keywords

aoac 98529
8
laboratory batches
8
fiber determination
8
repetitive aspects
8
[evaluation aoac
4
98529 enzimic
4
enzimic gravimetric
4
gravimetric method
4
determination
4
method determination
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!