Objectives: The hypothesis of this study was that three-dimensional ultrasound imaging would facilitate the evaluation of arterial dissection after balloon angioplasty.
Background: The presence and extent of arterial dissection occurring at the time of balloon angioplasty may be important predictors of abrupt vessel closure or late restenosis.
Methods: Forty-one human arterial segments obtained after death were imaged in an in vitro system at physiologic pressure (80 to 100 mm Hg) before and after balloon angioplasty. Images were acquired with a 20- to 30-MHz mechanical intravascular ultrasound imaging system (Cardiovascular Imaging Systems) with a constant pullback technique (1 mm/s). Standard 0.5-in. (1.27-cm) video tapes were used for data storage and later playback for analog to digital conversion. Digitized data were reconstructed to three-dimensional images with use of voxel space modeling. The vessels were opened longitudinally and subjected to pathologic examination, photographed and classified histologically as normal, fibrous or calcified. Dissection was defined as a disruption and separation of components of the arterial wall. The length and depth of arterial dissection were evaluated grossly and microscopically.
Results: Of the 41 arteries studied, 36 (88%) exhibited dissection on pathologic examination after balloon angioplasty. Three-dimensional reconstruction of intravascular ultrasound images identified dissection in 11 (92%) of 12 normal, 8 (100%) of 8 fibrous and 11 (69%) of 16 calcified arteries. Excellent agreement between ultrasound and pathologic findings was achieved in the evaluation of length and depth of dissection for histologically normal and fibrous arteries (kappa = 0.72 to 1.0). When the vessels were severely calcified, the agreement was not as good (kappa = 0.27 to 0.56), particularly in detection of small, non-raised intimal flaps.
Conclusions: This histopathologic validation study suggests that three-dimensional intravascular ultrasound imaging facilitates the evaluation of both quantitative and morphologic features of arterial dissection induced by balloon angioplasty. The advantage of three-dimensional intravascular ultrasound is its ability to assess the length and morphology of arterial injury over an entire vessel segment.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/0735-1097(92)90026-j | DOI Listing |
JACC Case Rep
January 2025
Division of Cardiovascular Disease, University of Alabama and Veterans Affairs Medical Center, Birmingham, Alabama, USA.
Percutaneous coronary intervention of a severely calcified coronary artery stenosis is associated with stent underexpansion and adverse outcomes. Intravascular lithotripsy (IVL) is a novel technology for fracturing calcified plaque in the coronary artery. We describe the first case of a severely calcified, undilatable coronary artery lesion.
View Article and Find Full Text PDFJACC Case Rep
January 2025
Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
Anomalous aortic origin of coronary artery can lead to ischemia. Due to the limitations of invasive catheterization dobutamine stress testing, an alternative noninvasive approach is desired. A 65-year-old woman with atypical chest pain was referred for coronary computed tomography angiography.
View Article and Find Full Text PDFJACC Case Rep
December 2024
Department of Cardiology, Centro Hospitalar Universitário Lisboa Norte,Centro Cardiovascular da Universidade de Lisboa (CCUL@RISE), Faculdade de Medicina da Universidade de Lisboa, Centro Académico de Medicina de Lisboa, Lisbon, Portugal.
An 80-year-old woman with a history of B-cell non-Hodgkin lymphoma presented to the emergency department with exertional dyspnea and lower limb edema. A transthoracic echocardiogram revealed a large extracardiac mass invading the right atrium. A diagnostic transcatheter endomyocardial biopsy guided by intracardiac echocardiography was performed.
View Article and Find Full Text PDFJ Vasc Surg Cases Innov Tech
April 2025
Atrium Health, Sanger Heart and Vascular Institute, Division of Vascular Surgery, Charlotte, NC.
We report a case of mesenteric ischemia after thoracic endovascular aortic repair (TEVAR) for chronic type B aortic dissection performed at a different institution. Computed tomography angiography findings indicated that the previous TEVAR had been deployed distally into the false lumen. To mitigate this, a large fenestration was created between the false lumen and true lumen.
View Article and Find Full Text PDFIntern Med
January 2025
Department of Cardiovascular Medicine, Nagasaki University Graduate School of Biomedical Sciences, Japan.
A 17-year-old Japanese boy was admitted to our hospital with intermittent claudication. He belonged to a weightlifting team at a high school. He had occasionally dropped lightweight lifting weights on his right foot.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!