This work describes the production and characterization of rabbit polyclonal antisera (pAb) and rat monoclonal antibodies (mAb) against isoproturon. Coating antigen and enzyme-tracer formats were developed. Standard curves for isoproturon were conducted either in 40 mM phosphate buffered saline (PBS) or in Milli-Q water. PAb 352 together with the best enzyme tracer revealed in the optimized ELISA (enzyme tracer format) a test midpoint of 1.06 +/- 0.34 microg/L (n = 19, standard set up in Milli-Q water) with a detection limit of about 0.1 microg/L. The comparable ELISA with mAb IOC 7E1 had test midpoints of 0.07 +/- 0.04 microg/L (n = 7, standards in Milli-Q water) and 0.11 +/- 0.08 microg/L (n = 33; standards in 40 mM PBS). The limits of detection were about 0.003 and 0.01 microg/L in Milli-Q water and PBS, respectively. Noticeable cross reactivities (CRs) were seen with the major metabolites, namely 4-isopropylaniline, 4-isopropylphenylurea, and 1-(4-isopropylphenyl)-3-methylurea. With pAb 352, these CRs were 5%, 7%, and 31%, respectively, and with mAb IOC 7E1, they were 3%, 5%, and ca. 19%, respectively. All arylurea herbicides had only minor CRs, which ranged from no CR (e.g., chlorosulfuron) to a maximum of 3.3% (chlortoluron). Influences of organic solvents (methanol, ethanol, acetonitrile, and acetone) were evaluated. Both pAb- and mAb-based immunoassays showed the highest tolerance for methanol, up to 5%. Ethanol and acetonitrile could not be used above 2% without an influence on the assays. The same was true for acetone, although tested only in the mAb-based assay. Water samples of different origins and matrices were spiked and analyzed with these pAb and mAb ELISAs. The results demonstrated that these immunoassays are useful screening tools.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/jf035498d | DOI Listing |
ACS Omega
December 2024
Professor, Department of Chemistry, ANITS College, Visakhapatnam 531162, India.
In this study, we reported a novel reverse-phase UPLC method for the simultaneous estimation of nitrite and nitrate ions using a Quality by Design (QbD) approach. Nitrite and nitrate ions were separated on an ACQUITY CSH Fluoro-Phenyl column (100 × 2.1 mm, 1.
View Article and Find Full Text PDFJDS Commun
November 2024
Department of Operative Dentistry, Cariology and Pulp Biology, Tokyo Dental College, Tokyo 101-0061, Japan.
We investigated the effect of bovine milk osteopontin (OPN) on the initial adhesion of to hydroxyapatite. Hydroxyapatite pellets were immersed in a 5.4 µ OPN solution at 37°C for 30 min.
View Article and Find Full Text PDFACS Appl Mater Interfaces
December 2024
Instituto Universitario de Tecnología Química (CSIC-UPV), Universitat Politècnica de València, Avda. de los Naranjos s/n, Valencia 46022, Spain.
Sci Total Environ
December 2024
State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products, Institute of Environment, Resource, Soil and Fertilizers, Zhejiang Academy of Agricultural Sciences, Hangzhou 310021, China. Electronic address:
Microalgal biochar has potential applications in various fields; however, there is limited research on the properties and risks of microalgal biochar-derived dissolved organic matter (MBDOM). This study examined how different pyrolysis temperatures (200 °C and 500 °C) and extraction solutions (0.1 mol/L HCl, Milli-Q water, and 0.
View Article and Find Full Text PDFWater Res
January 2025
MOE Key Laboratory of Pollution Processes and Environmental Criteria, College of Environmental Science and Engineering, Nankai University, Tianjin 300071, China.
Per- and polyfluoroalkyl substances (PFAS) have been widely used across various industries, leading to their prevalent occurrence in sludges generated by wastewater treatment plants (WWTPs). Consequently, industrial sludges serve as typical reservoirs for PFAS. This study examined 46 target PFAS in sludge samples intended for brick production from nine WWTPs in North China, identifying emerging PFAS and categorizing their behaviors through high-resolution mass spectrometry (HRMS) screening and total oxidizable precursor (TOP) assay.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!