Background And Purpose: Overviews of randomized patch trials by the Cochrane Collaboration suggest that a policy of routine patching is preferable to routine primary closure. However, there is no systematic evidence that patch type, whether prosthetic or vein, influences outcome after carotid endarterectomy (CEA).

Methods: Two hundred seventy-three patients were randomized to vein or thin-walled Dacron patch (Hemashield Finesse) closure of the arteriotomy after 276 CEA procedures. Patients were reviewed clinically and with duplex ultrasound scanning at 1, 6, 12, 24, and 36 months or until death. No patients were lost to follow-up. Cumulative statistical analyses are presented for the 264 patients (269 CEAs) who actually received a randomized treatment allocation.

Results: Cumulative freedom from death or ipsilateral stroke at 3 years (including operative events) was 93.0% in the Dacron patch group and 95.5% in the vein group P =.42). Cumulative freedom from death or any stroke was 91.5% after Dacron patch closure and 93.9% after vein closure (P =.46). Cumulative freedom from recurrent stenosis greater than 70% or occlusion at 3 years was 92.9% for patients randomized to the Dacron patch group and 98.4% for patients randomized to the vein group (P =.03). At 3 years the incidence of stroke in the carotid territory not operated on was 1.0% in 93 patients with no contralateral internal carotid artery disease at randomization, and increased to 1.3% in 78 patients with 1% to 69% stenosis, and 2.0% in 51 patients with contralateral 70% to 99% stenosis. No late strokes occurred distal to 42 occluded contralateral internal carotid arteries.

Conclusions: Patch type has no influence on early operative risk, no association with enhanced patterns of thrombogenicity in the early postoperative period, and no influence on risk for ipsilateral or any stroke at 3 years. Dacron patches were, however, associated with a significantly higher incidence of recurrent stenosis at 3 years, with most occurring within 6 to 12 months of surgery. However, the higher incidence of recurrent stenosis was not associated with a parallel increase in late stroke, and in this study a program of serial ultrasound surveillance could not have prevented one ipsilateral stroke.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jvs.2004.01.037DOI Listing

Publication Analysis

Top Keywords

dacron patch
16
patients randomized
12
cumulative freedom
12
ipsilateral stroke
12
recurrent stenosis
12
patients
9
carotid endarterectomy
8
patch type
8
randomized vein
8
freedom death
8

Similar Publications

A simplified approach to managing a complex infected left ventricular pseudoaneurysm.

J Cardiothorac Surg

December 2024

Heart Valve Disease Research Center, Rajaie Cardiovascular Medical and Research Center, Iran University of Medical Sciences, Tehran, Iran.

Background: Left ventricular pseudoaneurysm (LVP) is a rare but life-threatening condition resulting from acute myocardial infarction, trauma, bacterial infection, or previous cardiac operations. Diagnosis can be challenging as LVPs remain asymptomatic or present with nonspecific clinical symptoms. Early diagnosis is crucial to prevent rupture and recurrent septicemia.

View Article and Find Full Text PDF

Introduction And Importance: Traumatic injuries of the inferior Vena Cava (IVC) are rare among traumatic abdominal injuries. It accounts for fewer than 5 % of penetrating injuries and 0.5 % of blunt trauma injuries.

View Article and Find Full Text PDF

Background: Left ventricular pseudo-false aneurysm is a rare complication of myocardial infarction and generally caused by an intramyocardial dissecting hematoma due to a fragile myocardium. The serpiginous dissecting case of ventricular septal perforation has an entry port in the left ventricle and exit port in the right ventricle, and the entry port must be closed to leave the dissected chamber on the low-pressure right side for treatment. Herein, we report a case of a large left ventricular pseudo-false aneurysm that was unaccompanied by a shunt after the surgical repair of a ventricular septal dissection.

View Article and Find Full Text PDF

Case report: Surgical management of type 2 aortic dissection associated with bicuspid aortic valve and aortic coarctation.

SAGE Open Med Case Rep

October 2024

Department of Radiology, Cerrahpaşa Faculty of Medicine, İstanbul Üniversitesi-Cerrahpaşa, Istanbul, Turkiye.

This case report describes an exceptional case of aortic aneurysm co-occurring with type II dissection, bicuspid aortic valve, and severe aortic valve regurgitation in a patient with aortic coarctation. A 39-year-old man without any medical history was admitted to the hospital with chest pain. Physical examination revealed a holosystolic murmur and a noticeable blood pressure difference between the upper and lower extremities.

View Article and Find Full Text PDF

Complex Bentall Operation: Clinical Pearls to Standardize the Procedure.

Ann Thorac Surg

September 2024

Division of Cardiothoracic Surgery, Department of Surgery, Westchester Medical Center, New York Medical College, Valhalla, New York; Division of Cardiac Surgery, Department of Surgery, New York Medical College, Valhalla, New York.

Background: A straightforward Bentall operation can be performed safely with low mortality, but some challenging cases require a more complex operation. We discuss here the steps of the Bentall procedure.

Methods: We reviewed specific scenarios, such as acute aortic dissection, native valve or prosthetic valve endocarditis, redo Bentall after aortic root replacement, calcified aortic root, and patients with prior coronary artery bypass grafting, mechanical aortic valve replacement, stentless aortic valve replacement, and prior extensive aortic arch repair with proximalization of neck vessels.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!