Background: To determine the extended results of mechanical connectors we compared the 1-year outcomes of patients having beating heart coronary artery bypass surgery with at least one sutured or mechanically connected proximal vein graft anastomosis.
Methods: From May 2001 to December 2001, 166 patients were identified as having undergone off-pump bypass grafting utilizing at least one St. Jude symmetry aortic connector (St Jude Medical Anastomotic Technology Group, St. Paul, MN). Follow-up for major adverse cardiac events (MACEs), which is defined as cardiac mortality, myocardial infarction, or revascularization of a previous target vessel, was obtained on 162 patients (97.6%). A control group of 159 patients was identified from a cohort of patients having beating heart surgery with one or more sutured proximal vein graft anastomosis in the preceding year. The MACE follow-ups were obtained in 136 patients (85.6%) by direct telephone contact.
Results: Patients with connectors showed an accelerated number of MACEs beginning approximately 180 days from the time of surgery and stabilizing at approximately 300 days. Logistic regression analysis identified the presence of diabetes as a significant preoperative risk factor predisposing patients to earlier onset of MACEs (p = 0.03) with an odds ratio of 2.9 (95% confidence interval, 1.1 to 7.6). Insulin dependent diabetics showed no differences between connector and control patients in the frequency or timing of MACEs. Connector patients using oral hypoglycemic agents demonstrated a significant deviation (p = 0.01) from a similar control population in the prevalence and timing of MACEs.
Conclusions: Connector patients showed an increased incidence of early MACEs. These events were characterized by an increased requirement for early target vessel revascularization and were predominantly in noninsulin-dependent diabetics.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.athoracsur.2003.09.047 | DOI Listing |
J Cardiothorac Surg
January 2025
Department of Surgery, Division of Cardiac Surgery, Jefferson-Einstein Medical Center Philadelphia, Philadelphia, PA, USA.
Background: End-Stage Renal Disease (ESRD) is an independent risk factor in outcomes for traditional coronary artery bypass grafting (TRAD-CAB) utilizing aortic cross-clamping and cardioplegic arrest. In order to determine if Beating-Heart CABG (BH-CABG) techniques offer benefit in patients with ESRD, an analysis of the Society of Thoracic Surgeons (STS) predicted risk versus the actual outcomes was performed.
Methods: Between March 2017 - October 2023, all ESRD patients underwent BH-CABG by a single surgeon at a single institution.
Herzschrittmacherther Elektrophysiol
January 2025
Hannover Heart Rhythm Center, Department of Cardiology & Angiology, Hannover Medical School, Carl-Neuberg Str. 1, 30625, Hannover, Germany.
Background: The QRS axis of the electrocardiogram (ECG) is often considered in clinical practice, but its determination is frequently limited to a rough estimation, such as "normal", with left or right deviation, and superior or inferior in the case of premature ventricular complexes (PVCs). However, a more exact determination of the QRS axis may be warranted in certain scenarios, such as to determine the origin of PVCs more precisely, and is attainable by visual estimation using the hexaxial reference system.
Objectives: The aim of this study was to determine how well such an estimation of the QRS axis would correlate with the axis calculated by formulas.
BMJ Case Rep
January 2025
Cardiology, AIIMS, New Delhi, India
A young man in his 30s presented to us with multiple episodes of syncope and exertional dyspnoea for the last 2 weeks. He was diagnosed with squamous cell carcinoma of the lower one-third of the oesophagus in 2021 for which he was treated with neoadjuvant chemoradiotherapy, followed by McKeown oesophagectomy. At 2-year follow-up, he had developed a soft tissue swelling in the scalp, which was diagnosed as a tumour recurrence and radiotherapy was initiated.
View Article and Find Full Text PDFPhysiol Meas
January 2025
Department for Psychosomatic Medicine and Psychotherapy, Universitatsklinikum Jena, Philosophenweg 3, Jena, Thüringen, 07743, GERMANY.
Heart rate variability (HRV) is an important indicator of cardiac autonomic function. Given its clinical significance, reliable HRV assessment is crucial. Here, we assessed test-retest stability, as a key aspect of reliability, quantifying the consistency of a measure when repeated under the same conditions.
View Article and Find Full Text PDFSci Adv
January 2025
Department of Electrical and Computer Engineering, University of Illinois Urbana-Champaign, Urbana, IL 61801, USA.
Electrical stimulation of existing three-dimensional bioprinted tissues to alter tissue activities is typically associated with wired delivery, invasive electrode placement, and potential cell damage, minimizing its efficacy in cardiac modulation. Here, we report an optoelectronically active scaffold based on printed gelatin methacryloyl embedded with micro-solar cells, seeded with cardiomyocytes to form light-stimulable tissues. This enables untethered, noninvasive, and damage-free optoelectronic stimulation-induced modulation of cardiac beating behaviors without needing wires or genetic modifications to the tissue solely with light.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!